Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
statusinfo_5 | 4065 | Incmp Targ Rej | Incomplete Target Rejection - False target only partially captured; re-run False Target Rejection routine. | R | Enum | 2050 |
statusinfo_6 | 4066 | Scatter Target | Scattered Target - Return signals scattered due to turbulence in vessel. | R | Enum | 2050 |
statusinfo_7 | 4067 | Uncertn Target | Uncertain Target - Target is missing, but not determined to be lost; device is holding last valid value while confirming the target position, will continue based upon the LOE Delay value, consult Factory if problem persists. | R | Enum | 2050 |
statusinfo_8 | 4068 | DC Noise | DC Noise - Excessive noise on A/D channel; consult Factory. | R | Enum | 2050 |
statusinfo_9 | 4069 | Signal Too Hi | Signal Too High - Level signal amplitude is excessive; choose higher Dielectric range, reduce Turbulence or Foam settings, consult Factory if problem persists. | R | Enum | 2050 |
statusinfo_10 | 406A | Signal Too Low | Signal Too Low - Level signal amplitude is insufficient; choose lower Dielectric range, increase Turbulence or Foam settings, consult Factory if problem persists. | R | Enum | 2050 |
statusinfo_11 | 406B | Info 0800 | R | Enum | 2050 | |
statusinfo_12 | 406C | IPC Bus | IPC Bus - Internal communications error; consult Factory. | R | Enum | 2050 |
statusinfo_13 | 406D | IPC Checksum | IPC Checksum - Internal communications error; consult Factory. | R | Enum | 2050 |
statusinfo_14 | 406E | IPC Length | IPC Length - Internal communications error; consult Factory. | R | Enum | 2050 |
Name | ID | Label | Description | Type | Access | Class |