Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
BuildupPercentage | 488F | Percent of Level Threshold | Amplitude of the largest buildup signal in percent of the level threshold. | R | Unsigned | 2051 |
BuildupLocation | 4890 | Buildup Location | Location on the probe where buildup has occurred. Location is relative to the probe end. | R | Float | 2051 |
BuildupRate | 4891 | Buildup Rate | Change in buildup percentage per month. | R | Integer | 2051 |
electronics_temp | 4892 | Present Temperature | Displays present temperature measured in the electronics compartment. | R | Float | 2051 |
max_elec_temp | 4893 | Max Temperature | Maximum temperature measured in the electronics compartment. | R | Float | 2051 |
min_elec_temp | 4894 | Min Temperature | Minimum temperature measured in the electronics compartment. | R | Float | 2051 |
PCBTempOffset | 4895 | Elec Temp Offset | PCB temperature calibration value. Refer to I & O manual before adjusting. | R/W | Float | 2049 |
elec_temp_gauge_max | 4896 | Temperature USL | Defines the maximum usable value for the Upper Range Value. | R | Float | 0 |
elec_temp_gauge_min | 4897 | Temperature LSL | Defines the minimum usable value for the Lower Range Value. | R | Float | 0 |
Window | 4898 | Window | Factory parameter. Displayed for diagnostic purposes only. | R/W | Unsigned | 2048 |
Name | ID | Label | Description | Type | Access | Class |