Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
vol_set4mA | 40B2 | Vol 4mA Set Point | Defines the operational endpoint from which the Analog Value and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint from which the alarms associated with the Analog Value and the alarms associated with the Digital Value representation are derived. | R/W | Float | 64 |
vol_set20mA | 40B3 | Vol 20mA Set Point | Defines the operational endpoint from which the Analog Value and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint from which the alarms associated with the Analog Value and the alarms associated with the Digital Value representation are derived. | R/W | Float | 64 |
flo_set4mA | 40B4 | Flow 4mA Set Point | Defines the operational endpoint from which the Analog Value and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint from which the alarms associated with the Analog Value and the alarms associated with the Digital Value representation are derived. | R/W | Float | 64 |
flo_set20mA | 40B5 | Flow 20mA Set Point | Defines the operational endpoint from which the Analog Value and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint from which the alarms associated with the Analog Value and the alarms associated with the Digital Value representation are derived. | R/W | Float | 64 |
DTMDescription | 47C2 | Description | R/W | ASCII | 4096 | |
ProbeModel | 47C3 | Probe Model | Type of probe connected to the transmitter, as shown by the first four digits of the probe model number on the nameplate. Refer to the I/O Manual for additional information regarding different Probe Models. | R/W | Enum | 2048 |
ProbeCoating | 47C4 | Probe Coating | Presence of PFA coating on the probe rod. | R/W | Enum | 2048 |
ProbeMount | 47C5 | Probe Mount | Mounting style of probe process connection. | R/W | Enum | 2048 |
MeasType | 4097 | Measurement Type | The desired measurement mode of operation. (Selection of Measurement Type may be constrained by the Probe Model). | R/W | Enum | 2048 |
DielRange | 46A0 | Dielectric Range | A broad gain setting. The parameter selects the range bounding the dielectric constant of the medium being measured. For interface measurement mode, it selects the range bounding the dielectric constant of the lower liquid medium. Choose range 'Below 1.7' for very light hydrocarbons such as butane and propane. Choose range '1.7 - 3' for typical hydrocarbons and oils. Choose range '3 - 10' for amines. Choose range 'Above 10' for water-based applications. If uncertain, chose lower range setting for additional signal strength. (Some ranges may not be selectable depending on the probe model). | R/W | Enum | 2048 |