Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
ProbeType | 400A | Probe Type | Type of probe connected to transmitter | R/W | Enum | 2048 |
ProbeMount | 400B | Probe Mount | Mounting style of probe fitting | R/W | Enum | 2048 |
ProbeLength | 400C | Probe Length | Distance from face of process seal to end of probe | R/W | Float | 2048 |
Offset | 400D | Probe Offset | Desired level reading when liquid surface is at end of probe | R/W | Float | 2048 |
Dielectric1 | 400E | Dielectric | Dielectric constant of material in vessel. If unknown, use 'Varies'. | R/W | Enum | 2048 |
Set4mA | 400F | 4mA Set Point | Valor de endpoint de saída analógica- Define o endpoint inferior da respectiva saída analógica, para condições de operação normal | R/W | Float | 64 |
Set20mA | 4010 | 20mA Set Point | Valor de endpoint superior de saída analógica – Define o endpoint superior darespectiva saída analógica para as condições de operação normal | R/W | Float | 64 |
Fault | 4011 | Fault State | Tipo de alarme de saída analógica- Define como a saída analógica responderá quando o dispositivo de campo detectar a saída analógica poderá não seguir a variáveldo dispositivo de campo. NOTA- A representação do valor digital poderá não ser determinada. | R/W | Enum | 65 |
Initials | 4012 | Date/Time/Initials | When and by whom calibration was performed | R/W | PackedAscii | 2052 |
EnteredPassword | 4013 | Enter Password | Password is required for adjusting Advanced Setup parameters Magnetrol S/N and Device id, and Diagnostic-Digital Settings parameters Window, Range, Gain, Conversion Factor and Scale Offset | W | Unsigned | 2052 |