loc_TemperatureFadInlet | 4806 | Inlet Temperature | Enter the FAD inlet temperature (suction side) (Fct. C1.3.3) | 读/写 | 浮点 | 4096 |
bkp_TemperatureFadInlet | 4816 | Inlet Temperature | Enter the FAD inlet temperature (suction side) (Fct. C1.3.3) | 读/写 | 浮点 | 4096 |
loc_OptionOperatingValueCalculationDensity | 486B | Function | Switches the use of density limits on/off (Fct. C1.10.4.1) | 读/写 | 枚举 | 4096 |
bkp_OptionOperatingValueCalculationDensity | 4892 | Function | Switches the use of density limits on/off (Fct. C1.10.4.1) | 读/写 | 枚举 | 4096 |
loc_OperatingValueUserMinDensity | 486C | Min. Oper. Density | Minimum density of medium at operating pressure and temperature conditions for an application with changing density range. Value is used to calculate the lower sensor limit, if the according function is activated. (Fct. C1.10.4.2) | 读/写 | 浮点 | 4096 |
bkp_OperatingValueUserMinDensity | 4893 | Min. Oper. Density | Minimum density of medium at operating pressure and temperature conditions for an application with changing density range. Value is used to calculate the lower sensor limit, if the according function is activated. (Fct. C1.10.4.2) | 读/写 | 浮点 | 4096 |
loc_OperatingValueUserMaxDensity | 486D | Max. Oper. Density | Maximum density of medium at operating pressure and temperature conditions for an application with changing density range. Value is used to calculate the upper sensor limit, if the according function is activated. (Fct. C1.10.4.3) | 读/写 | 浮点 | 4096 |
bkp_OperatingValueUserMaxDensity | 4894 | Max. Oper. Density | Maximum density of medium at operating pressure and temperature conditions for an application with changing density range. Value is used to calculate the upper sensor limit, if the according function is activated. (Fct. C1.10.4.3) | 读/写 | 浮点 | 4096 |
loc_NominalDiameter | 486E | Nom. Diameter | Edit the nominal diameter of the measurement tube. (Fct. D1.2) | 读/写 | 枚举 | 4096 |
bkp_NominalDiameter | 4895 | Nom. Diameter | Edit the nominal diameter of the measurement tube. (Fct. D1.2) | 读/写 | 枚举 | 4096 |