Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
lstVolumeGas | 40AD | Limit Status | Limit Status 'LS' | R/W | Enum | 10 |
fstVolumeGas | 40AE | Family Status | Family Status 'FS' | R | BitEnum | 10 |
utpVolumeGas | 40AF | Update Time | Update Time Period 'UTP'. Indicates the maximum period between updates of the process variable. | R | Time | 8 |
simulateVolumeGas | 40B0 | Set Simulation | Desired setting of the process variable simulation. If enabled, the process variable will be simulated and won't show the actual process value. | W | Enum | 2048 |
propertiesVolumeGas | 40B1 | Properties | Properties, indicate e.g. the simulation state. | R | BitEnum | 10 |
dunMass | 40B3 | Unit Mass | Unit for mass. | R/W | Enum | 8 |
dfoMass | 40B5 | Format Mass | Display format for mass. Local for HART applications, no correlation with device's local display. | R/W | Enum | 4096 |
dvlMass | 40B4 | Mass | Mass process variable | R/W | Float | 10 |
uslMass | 40B6 | Upper Sensor Limit | Значение верхнего предела сенсора - определяет максимальное используемое значение для значения верхнего предела диапазона | R | Float | 8 |
lslMass | 40B7 | Lower Sensor Limit | Значение нижнего предела сенсора - определяет минимальное используемое значение для значения нижнего предела диапазона | R | Float | 8 |
Name | ID | Label | Description | Type | Access | Class |