Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
ssnCommon | 401D | Snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R/W | Unsigned | 8 |
dunVolumeFlow | 401F | Unit Volume Flow | Unit for Volume Flow. | R/W | Enum | 8 |
dfoVolumeFlow | 4021 | Format Volume Flow | Display format for Volume Flow. Local for HART applications, no correlation with device's local display. | R/W | Enum | 4096 |
dvlVolumeFlow | 4020 | Volume Flow | Volume Flow current measurement. | R/W | Float | 10 |
dmpVolumeFlow | 4023 | Time constant | Time constant for Volume Flow | R/W | Float | 8 |
uslVolumeFlow | 4024 | Upper Sensor Limit | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 8 |
lslVolumeFlow | 4025 | Lower Sensor Limit | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 8 |
mspVolumeFlow | 4026 | Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
clsVolumeFlow | 4027 | Class Volume Flow | Device Variable Class. Defines also the set of selectable physical units. | R | Enum | 8 |
dfaVolumeFlow | 4028 | Family | Device Variable Family | R | Enum | 8 |
Name | ID | Label | Description | Type | Access | Class |