Loading…
Name ID Label Description Type Access Class
dqaVolume12Totalizer2 4177 Data Quality Process Data Quality 'PDQ' R/W Enum 10
lstVolume12Totalizer2 4178 Limit Status Limit Status 'LS' R/W Enum 10
fstVolume12Totalizer2 4179 Family Status Family Status 'FS' R BitEnum 10
utpVolume12Totalizer2 417A Update Time Update Time Period 'UTP'. Indicates the maximum period between updates of the process variable. R Time 8
propertiesVolume12Totalizer2 417B Properties Properties, indicate e.g. the simulation state. R BitEnum 10
dunVolumeTotalizer3 417D Unit Volume Totalizer 3 Unit for Volume Totalizer 3. R/W Enum 8
dfoVolumeTotalizer3 417F Format Volume Totalizer 3 Display format for Volume Totalizer 3. Local for HART applications, no correlation with device's local display. R/W Enum 4096
dvlVolumeTotalizer3 417E Volume Totalizer 3 Volume Totalizer 3 current measurement. R/W Float 10
dmpVolumeTotalizer3 4180 Time constant Time constant for Volume Totalizer 3 R/W Float 8
uslVolumeTotalizer3 4181 Upper Sensor Limit Valor límite superior del sensor: Define el valor máximo utilizable para el valor de rango superior. R Float 8
Name ID Label Description Type Access Class