Loading…
Name ID Label Description Type Access Class
fstOperatingHours 4106 Family Status Family Status 'FS' R BitEnum 10
utpOperatingHours 4107 Update Time Update Time Period 'UTP' R Time 8
eSelectionAnalogOutput 4109 eSelectionAnalogOutput R/W Enum 4096
eSelectionCurrentOutput 410B eSelectionCurrentOutput R/W Enum 4096
aunPv 410F AO unit R Enum 64
uepPv 4110 AO hi end pt Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions R Float 64
lepPv 4114 AO lo end pt Analog Output Lower Endpoint Value- Defines the lower endpoint, of the respective Analog Output, for normal operating conditions R Float 64
adpPv 4115 Added damp Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. R Float 64
pcrSv 4117 SV % range Percent of range; tracks the associated measured value with respect to the range defined by the Lower Range Value and Upper Range Value. Frequency output D if available. R Float 34
tfcSv 4118 Xfer fnctn R Enum 32
Name ID Label Description Type Access Class