Loading…
Name ID Label Description Type Access Class
Volume_Unit 4047 Volume Unit Pick the volume unit to be displayed from the list. R/W Enum 2048
Mass_Unit 4046 Mass Unit Pick the mass unit to be displayed from the list. R/W Enum 2048
Length_Table_Unit 4048 Table Length Unit R/W Enum 8
Conversion_Unit 401B Conversion Unit Pick the conversion unit to be displayed from the list. The device can perform volume & mass conversion operations. If a mass conversion unit is directly selected here, a mass conversion table will be created (volume conversion will then not be possible). If a volume conversion unit is selected here, a volume conversion table will be created. This volume conversion table together with a product density greater than 0, could also be used to calculate mass. R/W Enum 8
Output_Function 401F Primary Function You can set the output function for output 1 (HART), scale the current values and change HART settings. R/W Enum 8
Blocking_Distance 4020 Blocking Distance The blocking distance defines the non-measuring range at the top of the probe.It depends on the installed probe type and installation type. R/W Unsigned 8
Reference_Offset 4021 Reference Offset Offset relating to a reference location (distance). This value shifts the reference point of the device to an external reference location. This value is positive when the reference location is above the device flange face and negative if below. R/W Integer 8
Tank_Bottom_Offset 4022 Tank Bottom Offset Offset relating to a reference location (level). This value shifts the reference point of the device to an external reference location. The device reference point for this parameter is the bottom of the tank, related to xxxxx 'Tank height'. This value is positive when the reference location is below the tank bottom and negative if above. R/W Integer 8
Density_Of_Product 4024 Product Density The device can perform volume and mass conversion operations. A volume conversion table together with a product density greater than 0, could be used to calculate mass. If a mass conversion unit has already been directly selected, this menu is disabled. A density of 0 disables the mass calculation. R/W Unsigned 8
Time_Constant 4026 Time Constant This function integrates several measurement readings, to filter out disturbances. Increasing the time constant[s] will smoothen the integrated readings, decreasing will roughen the readings. R/W Unsigned 8
Name ID Label Description Type Access Class