名称 ID 标签 描述 类型 访问 分类
output_error_delay 413B Output Error Delay The time after which the current output changes to an error value. The error value shows that there is a measurement error. 读/写 枚举 0
output_range 413A Output Range 读/写 枚举 64
output_function 4139 Output Function 读/写 枚举 64
display_length_unit 4137 Lenght Unit (On Local Display) 读/写 枚举 0
display_volume_unit 4138 Conversion Unit (On Local Display) 读/写 枚举 0
language 4136 Language 读/写 枚举 0
probe_length 4143 Probe Length Probe length is the distance from the flange face/thread stop of the device down to the bottom end of the probe (including counterweight for cable versions). 读/写 浮点 0
blocking_distance 4144 Block Distance The blocking distance defines the non-measuring range at the top of the probe. It depends on installed probe type and the installation type. 读/写 浮点 0
tank_height 4142 Tank Height Tank height is the distance from the tank connecting flange's top edge/thread stop down to the bottom of the tank. 读/写 浮点 0
time_constant 401D Time Constant New measured values are damped (filtered) with the time constant. Thus abrupt changes of the current output and the displayed values are damped. 读/写 浮点 0
名称 ID 标签 描述 类型 访问 分类