Name ID Label Description Type Access Class
volume_min_span 4037 Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
ullage_dig_value 403A Ullage Ullage Conversion R Float 10
Ullage_usl 403F USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 0
Ullage_lsl 4040 LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 0
Ullage_min_span 4041 Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
UllagePDQ 403B PDQ Process Data Quality 'PDQ' - Indicates the overall process data quality of the device variable value. R Enum 10
UllageLS 403C LS Limit Status 'LS' - Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 10
UllageStatus 403D Ullage Fmly stat Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 10
UllageUpdatePeriod 4042 Ullage Update Period R Time 0
UllageClassification 403E Ullage Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
Name ID Label Description Type Access Class