Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
trv_temperature_dig_units | 4099 | Temperature Units | Temperature display units. (Fct. 3.2.6) | R/W | Enum | 8 |
trv_temperature_dig_value | 401B | Temp M. | Measuring tube temperature | R | Float | 10 |
trv_temperature_sensor_units | 4124 | Snsr unit | R | Enum | 8 | |
trv_temperature_upper_sensor_limit | 406E | USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 8 |
trv_temperature_lower_sensor_limit | 406F | LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 8 |
trv_temperature_sensor_minimum_span | 4070 | Min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
trv_solute_flow_dig_units | 409C | Conc. Flow Units | Conc. Flow display units. (Fct. 3.2.8) | R/W | Enum | 16 |
trv_solute_flow_format | 409D | Conc. Flow Format | Conc. Flow display format. (Fct. 3.2.8) | R/W | Enum | 256 |
trv_solute_flow_dig_value | 401D | ConF | Conc. Flow | R | Float | 18 |
trv_solute_total_dig_units | 409E | Conc. Total Units | Conc. Total display units. (Fct. 3.2.9) | R/W | Enum | 16 |
Name | ID | Label | Description | Type | Access | Class |