Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
dvlVolTot | 4052 | Volume Totalizer | SV value; value of the totalizer (SV). | R/W | Float | 18 |
dvlNormalizedVolTot | 4062 | Volume Totalizer | SV value; value of the totalizer (SV). | R/W | Float | 18 |
dvlMassTot | 4071 | Volume Totalizer | SV value; value of the totalizer (SV). | R/W | Float | 18 |
dfoVolTot | 4053 | Totalizer format | Defines format specifier for totalizers' values, that is meaningful only for HART applications (FC375/FC475 screens, AMS faceplates, PDM, FDM...). Has no influence on the instrument display. | R/W | Enum | 4096 |
dfoNormalizedVolTot | 4063 | Totalizer format | Defines format specifier for totalizers' values, that is meaningful only for HART applications (FC375/FC475 screens, AMS faceplates, PDM, FDM...). Has no influence on the instrument display. | R/W | Enum | 4096 |
dfoMassTot | 4072 | Totalizer format | Defines format specifier for totalizers' values, that is meaningful only for HART applications (FC375/FC475 screens, AMS faceplates, PDM, FDM...). Has no influence on the instrument display. | R/W | Enum | 4096 |
dmpVolTot | 4054 | Totalizer damping | Reaction of the measured value according to process changes; after this time the output value increases to 63% of change in process. | R/W | Float | 32 |
dmpNormalizedVolTot | 4064 | Totalizer damping | Reaction of the measured value according to process changes; after this time the output value increases to 63% of change in process. | R/W | Float | 32 |
dmpMassTot | 4073 | Totalizer damping | Reaction of the measured value according to process changes; after this time the output value increases to 63% of change in process. | R/W | Float | 32 |
uslVolTot | 4056 | Upper total limit | Upper sensor limit for Totalizer; fixed point (999e12 cum). | R | Float | 8 |
Name | ID | Label | Description | Type | Access | Class |