Name ID Label Description Type Access Class
CompressibilityFactor_3011 4094 Compressibility Compressibility factor; specifies the deviation between the real gas and ideal gas. R Float 2048
ConeCode_3012 4095 Type of cone Type of cone, shows the used type of cone. R Enum 2048
FloatCode_3013 4096 Type of float Type of float; manufacturer code for used type of float. R Enum 2048
FloatMaterialCode_3014 4097 Material of float Material of float; shows the used material of float. R Enum 2048
MeterTypeCode_3015 4098 Meter type Meter type; manufacturer code for used meter type. R Enum 2048
MeterSizeCode_3017 4099 Nominal meter size Nominal meter size; nominal meter size of used measuring tube. R Enum 2048
Low_flow_cutoffOnLFC_3659 409A LFC on value Lfc on value; if PV (primary measurand) falls below this value, the measurement scale is set to zero (adjustable between 1% and 19%). R/W Float 2048
Low_flow_cutoffOffLFC_3660 409B LFC off value Lfc off value; if PV (primary measurand) exceeds this value, the measurement scale follows the actual flow rate (adjustable between 2% and 20%). R/W Float 2048
Low_flow_cutoffSwitch_3661 409C LFC control Lfc control; switching the lfc on or off. R/W Enum 2048
TimeConstantFormerDamping_value_3662 400B Time constant Time constant of process input R/W Float 2048
Name ID Label Description Type Access Class