Loading…
Name ID Label Description Type Access Class
utpMassFlow 4032 Update Time Update Time Period 'UTP'. Indicates the maximum period between updates of the process variable. R Time 8
simulatedMassFlow 4033 Set Simulation Desired setting of the process variable simulation. If enabled, the process variable will be simulated and won't show the actual process value. W Enum 2048
prpMassFlow 4034 Properties Properties, indicate e.g. the simulation state. R BitEnum 10
dunVolumeLiquid 4036 Unit Volume Unit for Volume. R/W Enum 8
dfoVolumeLiquid 4038 Format Volume Display format for Volume. Local for HART applications, no correlation with device's local display. R/W Enum 4096
dvlVolumeLiquid 4037 Volume Volume current measurement. R/W Float 10
uslVolumeLiquid 4039 Upper Sensor Limit Valor límite superior del sensor: Define el valor máximo utilizable para el valor de rango superior. R Float 8
lslVolumeLiquid 403A Lower Sensor Limit Valor límite inferior del sensor: Define el valor mínimo utilizable para el valor de rango inferior. R Float 8
mspVolumeLiquid 403B Minimum Span Valor de span mínimo: Define la menor diferencia permitida entre el valor de rango superior y el valor de rango inferior. R Float 8
clsVolumeLiquid 403C Class Volume Device Variable Class. Defines also the set of selectable physical units. R Enum 8
Name ID Label Description Type Access Class