Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
lin_output_20 | 4082 | Output Point 20 | R/W | Float | 2048 | |
lin_level_value | 406E | Linearized Output | Linearized Output - The output of the linearization table based on Level | R | Float | 10 |
test_xtal | 4027 | R/W | Unsigned | 2048 | ||
rx_bias | 402D | RX Bias | R/W | Unsigned | 2048 | |
laser_pump_bias | 402C | Laser Pump Bias | R/W | Unsigned | 2048 | |
signal_strength | 402E | Signal Strength | R | Float | 2048 | |
input_upper_value | 4104 | PV URV | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
input_lower_value | 4105 | PV LRV | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
sensor_serial_number | 4103 | PV Snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 2048 |
sensor_upper_limit | 40FF | PV USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 8 |
Name | ID | Label | Description | Type | Access | Class |