Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
xtal_a_start | 4016 | XTAL_A Start | Max = 235 Min = 225 | R | Unsigned | 2048 |
xtal_b_start | 4017 | XTAL_B Start | Max = 100 Min = 25 | R | Unsigned | 2048 |
sweep_limits | 4018 | Sweep Limits | Max = 8 Min = 3 | R | Unsigned | 2048 |
sweep_counts_23m | 4019 | Sweep Counts @ 23m | Max = 2000 Min = 1000 | R | Unsigned | 2048 |
fpga_param_index | 410E | R/W | Index | 4096 | ||
sw_revision_date | 4001 | Software Build | R | HartDate | 2048 | |
fill_rate_light_dust | 40C3 | LD-Fill Rate | Default: 0.00 ft./min. Material level increase in silo under fill conditions. Default is 0.00 ft./min. When set to 0.00 ft./min, fill rate is not active. | R/W | Float | 2048 |
empty_rate_light_dust | 40C4 | LD-Empty Rate | Default: 0.00 ft./min. Material level decrease in silo under discharge conditions. Default is 0.00 ft./min. When set to 0.00 ft./min, empty rate is not active. | R/W | Float | 2048 |
range_blank_light_dust | 40C5 | LD-Range Blank | Default: 0.00 ft. Distance at which is possible for laser to lose signal due to reflecting from polished surface. Example: Stainless Steel vessels in food processing industry. | R/W | Float | 2048 |
buffer_light_dust | 40C6 | LD-Buffer | Default: 25. Filtering system of the instrument. Change only according to applications specifi cs. | R/W | Unsigned | 2048 |
Name | ID | Label | Description | Type | Access | Class |