名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
actual_interface | 42B5 | 写 | 浮点 | 2048 | ||
raw_interface | 42B6 | Raw Interface | Raw Interface - The raw count measured for the interface | 读 | 无符号 | 2050 |
alarm_delay | 4034 | Alarm Delay | 读/写 | 浮点 | 2048 | |
sw_revision_str | 404E | Software Version | 读 | ASCII | 2048 | |
lin_table_input_index | 404F | 读 | 索引 | 4096 | ||
lin_table_point | 4051 | 写 | 无符号 | 2048 | ||
lin_units | 4011 | Linearization Units | LIN UNITS allows the selection of the desired output UNITS for the linearization table. LIN UNITS can be in Level, %, Volume or Flow units. Please see the Installation & Maintenance Manual or menu contents for unit options. | 读/写 | 枚举 | 2048 |
lin_mode | 4052 | Linearization Mode | Determines how the values in the table will be assigned; either by entering the input values manually or by raising the tank level and entering the values automatically. - Manual Mode allows the entry of the input values along with the desired respective output level. - Automatic mode requires the level of the product to be at the measured level when the respective output value is set. NOTE: Manual mode will produce a more exact linearization profile compared to Automatic mode. | 读/写 | 枚举 | 2048 |
lin_minimum | 4053 | Linearization Minimum | The value assigned to the lowest measurable point along the PROBE LENGTH. Typically this will be set to 0, although it is not required. | 读/写 | 浮点 | 2048 |
lin_maximum | 4054 | Linearization Maximum | The value assigned to the highest measurable point along the PROBE LENGTH. This value must be greater than the largest value entered in the Linearization Table. | 读/写 | 浮点 | 2048 |
名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |