名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
probe_type | 401A | Probe Type | This function will help adjust the transmitter setting for the installed configuration. Certain aspects of the transmitter setup will be adjusted to conform to the probe type selected. Selectable probe types include: Single Rod/Cable, Dual Rod/Cable or Coaxial. Select only the type of probe mounted to the MT5xxx transmitter. Failure to set the correct probe type could result in measurement errors. | 读/写 | 枚举 | 2048 |
mounting_type | 401B | Mounting Type | Mounting configurations will affect probe types in different ways. A sensor mounted on a nozzle whose length is greater than its width could cause a reduced signal capacity which must be accounted for by the MT5xxx. The MOUNTING TYPE corresponding to the installation must be entered correctly. The MOUNTING TYPE should fall into one of the categories listed below:
PLATE - a flat surface roof or metal disk used for signal launch
COUPLING PLATE - a coupling or nipple fitting welded to a flat ceiling or launch plate.
NOZZLE/FLANGE H>S - A nozzle with a greater height than diameter.
NOZZLE/FLANGE H读/写 |
枚举 |
2048 |
|
probe_length | 401D | Probe Length | Also described as insertion length, PROBE LENGTH is the measured distance from the bottom thread of the process fitting (or the face of the flange) to the end of the probe. This value must be entered in units that correspond to the UNITS parameter. | 读/写 | 浮点 | 2048 |
blanking_distance | 401E | Blanking Distance | Blanking is a measured area which the MT5xxx will be set to ignore INCLUDING the nozzle distance. It may be necessary to extend the Blanking further past the nozzle to ignore reflections from the top portion of the probe. Blanking is set in terms of UNITS. To adjust the Blanking, enter the distance from the Reference Measurement to be ignored. Do not blank into your measuring range. Signal will be lost. | 读/写 | 浮点 | 2048 |
level_offset | 401F | Level Offset | Offset is a parameter which may be used to compensate for an un-measureable area below a probe OR to align the measurement of the MT5xxx with another device. The value entered in the Offset will be Added to or subtracted from the LVL indication on the main display as well as the output signal. Example: If the end of the probe were 4 inches off the bottom of the tank, the OFFSSET would be 4 inches. If the actual Measured Level were 21 inches after entering the OFFSET, the local indicator would indicate 25 inches (21 +4) and the output signal would indicate a level of 25 inches. | 读/写 | 浮点 | 2048 |
interface_offset | 42B0 | Inteface Offset | INTERFACE OFFSET is a parameter which may be used on the interface reading to add or subtract from the Interface indication on the main display and transmitter output. 2Example: If the interface reading were 4 inches below the expected reading and reading 36 inches, the INTERFACE OFFSET would be 4 inches. If the measured INTERFACE LVL was 40 inches after entering the OFFSET, the local indicator would read 40 inches (36 +4) and the output signal would indicate a level of 40 inches. | 读/写 | 浮点 | 2048 |
gas_phase_dielectric | 4020 | Gas Phase Dielectric | 读/写 | 浮点 | 2048 | |
upper_dielectric | 4021 | Upper Dielectric | The DIELECTRIC setting is an optional entry. It is not used to set or establish any operating parameters within the unit. It will not be necessary to know the exact dielectric constant of the process or to enter a valid value in this setting. NOTE: If the application was for interface measurement, you would need to use the parameter UPPER DIELECTRIC. | 读/写 | 浮点 | 2048 |
lower_dielectric | 42B1 | Lower Dielectric | The LOWER DIELECTRIC is the dielectric constant value of the interface fluid. This setting is an optional entry. It is not used to set or establish any operating parameters within the unit. It will not be necessary to know the exact dielectric constant of the process or to enter a valid value in this setting. | 读/写 | 浮点 | 2048 |
language | 4022 | Language | The MT5xxx has been equipped with several different operating languages to assist in the setup of the unit. When a specific language is selected, the titles of the menu items will be translated. Abbreviations specific to the MT5xxx will remain unchanged as icons regardless of language selection. Available LANGUAGES include: o English o French o Spanish o Portuguese o Italian o Russian o Chinese (Mandarin). | 读/写 | 枚举 | 2048 |