Name ID Label Description Type Access Class
Sens_DataC 4019 Data [C] Results from the measurement process. R Float 2051
Sens_DataD 401A Data [D] Results from the measurement process. R Float 2051
Mea_OffsetV 401B V Offset Voltage Channel Offset. Typically 625 millivolts +/- 6. R/W Float 0
Mea_OffsetI 401C I Offset Current Channel Offset. Typically 625 millivolts +/- 6. R/W Float 0
PV_Avg 401D PV Avg Average of the selected measurement over the number of mearurement cycles since these were last cleared. R Float 18
PV_Cnt 401E Samp Count The number of measurement cycles since last cleared. R Unsigned 18
PV_val 401F PV Selected measurement output. Type1 in mm/yr or mil/yr or Type2 R Float 34
PV_urv 4020 URV Selected measurement upper output limit. Not applicable if Preference is set to Type2. If the alarm is enabled, the loop current will go to alarm condition if the measured value exceeds this limit. R/W Float 0
Sens_hilim 4021 Sens Max Sensor selected measurement maximum. 1000.0 for mm/yr, 40000.0 for mil/yr, 1.0 for Preference set to Type2 R Float 0
PV_lrv 4022 LRV Selected measurement lower output limit. Not applicable if Preference is set to Type2. If the alarm is enabled, the loop current will go to alarm condition if the measured value exceeds this limit. R/W Float 0
Sens_lolim 4023 Sens Min Sensor selected measurement minimum. 0.0 for any output selection R Float 0
PV_span 4024 Min Span Selected measurement minimum span. 1.0 if mm/yr, 40.0 if mil/yr. Not applicable if Preference is set to Type2. R Float 0
PV_mA 4025 AO1 Valor de salida analógica: Valor que sigue la representación del valor digital, bajo modos de funcionamiento normales R/W Float 66
PV_percent 4026 PV % rnge Porcentaje de rango: Variable que rastrea la representación del valor digital con respecto al rango definido por el valor de rango inferior y el valor de rango superior, para modos de funcionamiento normales. Las unidades de esta variable siempre son en porcentaje. R Float 34
PV_damp 4027 Damping Measurement damping time in seconds. R/W Float 8
PV_Xfr 4028 Xfr Code Transfer Function Code R Enum 0
PV_Units 4029 PV Units Selected Ouput Variable Units if Type1, mm/yr or mil/yr, else if Type2, none R/W Enum 0
sensor_serial_number 402A PV Snsr s/n Número de serie del sensor: Identifica de manera única el sensor del que se deriva principalmente la representación del valor digital o la variable del dispositivo de campo. R Unsigned 2048
Dummy_password 402B Dummy Password R ASCII 4096
Dummy_units 402C Dummy Units R Unsigned 2048
MV_PW 402D MV Pswd Eight character password W ASCII 0
MV_PWstate 402E MV Pswd St Password enabled indicator, 0 = diasbled, 1 = enabled R Enum 0
MV_Mode 402F MV Mode MV Mode. Disabled or Enabled. W Enum 0
SV_val 4031 Local Corrosion Secondary measurement output. R Float 34
TV_val 4032 Stern-Geary Tertiary measurement output. R Float 34
Name ID Label Description Type Access Class