Name ID Label Description Type Access Class
loop_alarm_code 00EC PV AO Alm Type AO Alarm Type - Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. Analog Output - Measurable physical output which changes with respect to time, without user intervention. R Enum 66
loop_flags 00E7 Sinalizadores de canal Sinalizadores de canal analógicos- Define as características do canal analógico R BitEnum 64
percentRange 00E9 PV % Percent of Range - Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. PV - Pressure of the process measured with respect to a reference pressure. R Float 34
transfer_function 1F84 Xfer Fn Transfer Function - Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. PV - Pressure of the process measured with respect to a reference pressure. R/W Enum 32
upperRange_value 00EA PV URV URV - Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. PV - Pressure of the process measured with respect to a reference pressure. R/W Float 32
lowerRange_value 00EB PV LRV LRV - Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. PV - Pressure of the process measured with respect to a reference pressure. R/W Float 32
eeprom_select 0FAB Seleção EEPROM Leitura para apagar eletronicamente de seleção de memória- Controla os dados em: Leitura EEPROM somente memória / somente memória de leitura. R/W Enum 4096
device_variable_code 1047 Device Variable Índice para dentro da matriz dinâmica das variáveis- Um índice que identifica uma variável do dispositivo de campo que seja dinâmico em relação ao tempo, sem um usuário de entrada R/W Index 4096