Loading…
Name ID Label Description Type Access Class
pressure_lower_transducer_limit 400E LTL LTL - Defines the lowest acceptable value for the Transducer. LTL = -2*URL (Unit same as PV) if DP type LTL = 0 (Unit same as PV) if AP or GP type SPAN cannot be greater than UTL R Float 8
pressure_units 138D PV unit PV Unit - Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. PV - Pressure of the process measured with respect to a reference pressure. R/W Enum 8
pressure_units_SP 400F TV unit TV (Static Pressure) Unit - Engineering unit to be displayed with the Digital Value representation R Enum 8
pressure_damping_value 1398 PV Damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Float 8
pressure_minimum_span 1390 Pres min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. PV - Pressure of the process measured with respect to a reference pressure. R Float 8
pressureClassificationCode 4010 R Enum 0
pressureDQ 4011 R Enum 10
pressureLS 4012 R Enum 10
pressureStatus 4013 R BitEnum 10
pressure_sensor_serial_number 1770 MB S/N Meter Body Serial Number - Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. PV Sensor- Pressure hardware that measures pressure with respect to a reference pressure. R Unsigned 2048
Name ID Label Description Type Access Class