Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
ePWMFreqModeRelayD | 410D | Auto, the relay output works as a PID controller. Manual, the relay output has an On/Off ratio as set in the PI Manual setting. | R/W | Enum | 0 | |
iPWMFreqIntegralRelayA | 4161 | Sets the integral part of the PID controller. | R/W | Unsigned | 0 | |
iPWMFreqIntegralRelayB | 4162 | Sets the integral part of the PID controller. | R/W | Unsigned | 0 | |
iPWMFreqIntegralRelayC | 4163 | Sets the integral part of the PID controller. | R/W | Unsigned | 0 | |
iPWMFreqIntegralRelayD | 4164 | Sets the integral part of the PID controller. | R/W | Unsigned | 0 | |
eRangeRelayA | 4165 | Range A | Selection List of sensor ranges. | R | Enum | 0 |
eRangeRelayB | 4166 | Range B | Selection List of sensor ranges. | R | Enum | 0 |
eRangeRelayC | 4167 | Range C | Selection List of sensor ranges. | R | Enum | 0 |
eRangeRelayD | 4168 | Range D | Selection List of sensor ranges. | R | Enum | 0 |
eFailSafeModeRelayA | 4169 | Fail Safe Mode A | Fail Safe Mode 'ON' implies the relay is energized in the non-alarm state. | R/W | Enum | 0 |
eFailSafeModeRelayB | 416A | Fail Safe Mode B | Fail Safe Mode 'ON' implies the relay is energized in the non-alarm state. | R/W | Enum | 0 |
eFailSafeModeRelayC | 416B | Fail Safe Mode C | Fail Safe Mode 'ON' implies the relay is energized in the non-alarm state. | R/W | Enum | 0 |
eFailSafeModeRelayD | 416C | Fail Safe Mode D | Fail Safe Mode 'ON' implies the relay is energized in the non-alarm state. | R/W | Enum | 0 |
iOneHighFloatIndexSC200 | 4177 | R/W | Index | 4096 | ||
rNetworkPortPercentGoodMsg | 4179 | Net Port % Good Msg | Percentage of good messages on the Network Card Port. | R | Float | 2049 |
rServicePortPercentGoodMsg | 417A | Svc Port % Good Msg | Percentage of good messages on the Service Port. | R | Float | 2049 |
rPort1PercentGoodMsg | 417B | Port 1 % Good Msg | Percentage of good messages on Port 1. | R | Float | 2049 |
rPort2PercentGoodMsg | 417C | Port 2 % Good Msg | Percentage of good messages on Port 2. | R | Float | 2049 |
rPort3PercentGoodMsg | 417D | Port 3 % Good Msg | Percentage of good messages on Port 3. | R | Float | 2049 |
rPort4PercentGoodMsg | 417E | Port 4 % Good Msg | Percentage of good messages on Port 4. | R | Float | 2049 |
rTestTemperature | 417F | Current Temperature | Internal temperature of the sc200. | R | Float | 9 |
rTest12V | 4180 | 12V Supply Voltage | Measured value of the sc200 12 volt supply. | R | Float | 2049 |
rTest3V3Current | 4181 | 3.3V Supply Current | Total 3.3V Supply current (A). | R | Float | 2049 |
rTest12VCurrent | 4182 | 12V Supply Current | Total 12V Supply current (A). | R | Float | 2049 |
rTestPort3Current | 4183 | Port 3 Supply Current | Smart Sensor 1 - 12V Supply current (A). | R | Float | 2049 |
rTestPort4Current | 4184 | Port 4 Supply Current | Smart Sensor 2 - 12V Supply current (A). | R | Float | 2049 |
rTestPort1Current | 4185 | Port 1 Supply Current | Analog Sensor 1 - 12V Supply current (A). | R | Float | 2049 |
rTestPort2Current | 4186 | Port 2 Supply Current | Analog Sensor 2 - 12V Supply current (A). | R | Float | 2049 |
rMaxTemperature | 4187 | Max Temperature | The daily maximum sc200 internal temperature in C. | R | Float | 9 |
rMinTemperature | 4188 | Min Temperature | The daily minimum sc200 internal temperature in C. | R | Float | 9 |
rTest12VGround | 4189 | 12V Ground Potential | The measured voltage between A/D common and the 12 volt supply ground. | R | Float | 5 |
rTestOutput1Value | 418A | Output 1 Value | Display or Set level on Output 1. | R/W | Float | 5 |
rTestOutput2Value | 418B | Output 2 Value | Display or Set level on Output 2. | R/W | Float | 5 |
iOneHighUnsignedIntegerIndexSC200 | 418F | R/W | Index | 4096 | ||
eClearEventLogs | 4191 | R/W | Enum | 0 | ||
eClearDataLogs | 4192 | R/W | Enum | 0 | ||
bNetworkError | 4193 | Network Errors | Sensor communication error flags. | R | BitEnum | 2051 |
bNetworkStatus | 4194 | Network Status | Sensor communication and relay status. | R | BitEnum | 2051 |
eSetDefaults | 4195 | R/W | Enum | 0 | ||
eTestOutputEnable1 | 4196 | Test Enable Out 1 | Enables test of Output 1. | R/W | Enum | 4 |
eTestOutputEnable2 | 4197 | Test Enable Out 2 | Enables test of Output 2. | R/W | Enum | 4 |
iCalibrateOutput4mA1 | 4198 | Cal 4 mA Out 1 | Calibration counts for 4 mA Output 1. | R | Unsigned | 4 |
iCalibrateOutput4mA2 | 4199 | Cal 4 mA Out 2 | Calibration counts for 4 mA Output 2. | R | Unsigned | 4 |
iCalibrateOutput20mA1 | 419A | Cal 20 mA Out 1 | Calibration counts for 20 mA Output 1. | R | Unsigned | 4 |
iCalibrateOutput20mA2 | 419B | Cal 20 mA Out 2 | Calibration counts for 20 mA Output 2. | R | Unsigned | 4 |
eTestRelayEnableA | 419C | Test Relay A Enable | Enables test of Relay A. | R/W | Enum | 4 |
eTestRelayEnableB | 419D | Test Relay B Enable | Enables test of Relay B. | R/W | Enum | 4 |
eTestRelayEnableC | 419E | Test Relay C Enable | Enables test of Relay C. | R/W | Enum | 4 |
eTestRelayEnableD | 419F | Test Relay D Enable | Enables test of Relay D. | R/W | Enum | 4 |
eTestRelayValueA | 41A0 | Test Relay A Value | Sets the test state for Relay A. | R/W | Enum | 4 |