Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
iPort1StatsBadMsg | 41BF | Port 1 Bad Msg | Number of bad messages on Port 1. | R | Unsigned | 1 |
iPort2StatsGoodMsg | 41C0 | Port 2 Good Msg | Number of good messages on Port 2. | R | Unsigned | 1 |
iPort2StatsBadMsg | 41C1 | Port 2 Bad Msg | Number of bad messages on Port 2. | R | Unsigned | 1 |
iPort3StatsGoodMsg | 41C2 | Port 3 Good Msg | Number of good messages on Port 3. | R | Unsigned | 1 |
iPort3StatsBadMsg | 41C3 | Port 3 Bad Msg | Number of bad messages on Port 3. | R | Unsigned | 1 |
iPort4StatsGoodMsg | 41C4 | Port 4 Good Msg | Number of good messages on Port 4. | R | Unsigned | 1 |
iPort4StatsBadMsg | 41C5 | Port 4 Bad Msg | Number of bad messages on Port 4. | R | Unsigned | 1 |
sMathUnits | 41C7 | Math Units | Six character measurement unit for the sc200 Calculated Value. | R | ASCII | 2048 |
sMathParameters | 41C8 | Math Parameters | Six character measurement parameter for the sc200 Calculated Value. | R | ASCII | 2048 |
sDigitalSensor1Connected | 41DE | Sensor 1 Status | Sensor 1 Installation Status. | R | ASCII | 4096 |
sDigitalSensor2Connected | 41DF | Sensor 2 Status | Sensor 2 Installation Status | R | ASCII | 4096 |
rLoop1Current | 422A | Loop 1 Current | Corrente di loop - Valore della corrente di loop come percepito dal dispositivo. | R/W | Float | 66 |
rLoop2Current | 422B | Loop 2 Current | Corrente di loop - Valore della corrente di loop come percepito dal dispositivo. | R/W | Float | 66 |
rLoopACurrent | 4223 | Loop A Current | Corrente di loop - Valore della corrente di loop come percepito dal dispositivo. | R/W | Float | 66 |
eLoopAAlarmCode | 4224 | Alarm A Select | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. | R | Enum | 64 |
bLoopAFlags | 4225 | Loop A Flags | Analog Channel Flags- Defines the characteristics of the Analog Channel | R/W | BitEnum | 64 |
rLoopBCurrent | 4226 | Loop B Current | Corrente di loop - Valore della corrente di loop come percepito dal dispositivo. | R/W | Float | 66 |
eLoopBAlarmCode | 4227 | Alarm B Select | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. | R | Enum | 64 |
bLoopBFlags | 4228 | Loop B Flags | Analog Channel Flags- Defines the characteristics of the Analog Channel | R | BitEnum | 64 |
rLoopCCurrent | 4229 | Loop C Current | Corrente di loop - Valore della corrente di loop come percepito dal dispositivo. | R/W | Float | 66 |
eLoopCAlarmCode | 422F | Alarm C Select | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. | R | Enum | 64 |
bLoopCFlags | 4230 | Loop C Flags | Analog Channel Flags- Defines the characteristics of the Analog Channel | R | BitEnum | 64 |
cAnalogChannelIndex | 4231 | R/W | Index | 4096 | ||
iHARTLowFloatIndex | 4236 | R/W | Index | 4096 | ||
rMinimumSettingLoopA | 405E | LRV Loop A | Lower Range Value Loop A. | R/W | Float | 66 |
Name | ID | Label | Description | Type | Access | Class |