Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
eResetOverfeedTimerRelayC | 414B | Reset Overfeed Timer C | Resets the Overfeed Timer for Relay C | R/W | Enum | 0 |
eResetOverfeedTimerRelayD | 414C | Reset Overfeed Timer D | Resets the Overfeed Timer for Relay D | R/W | Enum | 0 |
iOnMaxTimeEventRelayA | 414D | Max On Time A | Sets the maximum time the relay can remain on. | R/W | Unsigned | 0 |
iOnMaxTimeEventRelayB | 414E | Max On Time B | Sets the maximum time the relay can remain on. | R/W | Unsigned | 0 |
iOnMaxTimeEventRelayC | 414F | Max On Time C | Sets the maximum time the relay can remain on. | R/W | Unsigned | 0 |
iOnMaxTimeEventRelayD | 4150 | Max On Time D | Sets the maximum time the relay can remain on. | R/W | Unsigned | 0 |
iOnMinTimeEventRelayA | 4151 | Min On Time A | Sets the time the relay will remain on independent from the measured value. | R/W | Unsigned | 0 |
iOnMinTimeEventRelayB | 4152 | Min On Time B | Sets the time the relay will remain on independent from the measured value. | R/W | Unsigned | 0 |
iOnMinTimeEventRelayC | 4153 | Min On Time C | Sets the time the relay will remain on independent from the measured value. | R/W | Unsigned | 0 |
iOnMinTimeEventRelayD | 4154 | Min On Time D | Sets the time the relay will remain on independent from the measured value. | R/W | Unsigned | 0 |
iOffMaxTimeEventRelayA | 4155 | Max Off Time A | Sets the maximum time the relay can remain off. | R/W | Unsigned | 0 |
iOffMaxTimeEventRelayB | 4156 | Max Off Time B | Sets the maximum time the relay can remain off. | R/W | Unsigned | 0 |
iOffMaxTimeEventRelayC | 4157 | Max Off Time C | Sets the maximum time the relay can remain off. | R/W | Unsigned | 0 |
iOffMaxTimeEventRelayD | 4158 | Max Off Time D | Sets the maximum time the relay can remain off. | R/W | Unsigned | 0 |
iOffMinTimeEventRelayA | 4159 | Min Off Time A | Sets the time the relay will remain off independent from the measured value. | R/W | Unsigned | 0 |
iOffMinTimeEventRelayB | 415A | Min Off Time B | Sets the time the relay will remain off independent from the measured value. | R/W | Unsigned | 0 |
iOffMinTimeEventRelayC | 415B | Min Off Time C | Sets the time the relay will remain off independent from the measured value. | R/W | Unsigned | 0 |
iOffMinTimeEventRelayD | 415C | Min Off Time D | Sets the time the relay will remain off independent from the measured value. | R/W | Unsigned | 0 |
iWarningLevelStatusRelayA | 415D | Warning Level A | Sets the level for device warning activation. | R/W | Unsigned | 0 |
iWarningLevelStatusRelayB | 415E | Warning Level B | Sets the level for device warning activation. | R/W | Unsigned | 0 |
iWarningLevelStatusRelayC | 415F | Warning Level C | Sets the level for device warning activation. | R/W | Unsigned | 0 |
iWarningLevelStatusRelayD | 4160 | Warning Level D | Sets the level for device warning activation. | R/W | Unsigned | 0 |
ePWMFreqModeRelayA | 4107 | Auto, the relay output works as a PID controller. Manual, the relay output has an On/Off ratio as set in the PI Manual setting. | R/W | Enum | 0 | |
ePWMFreqModeRelayB | 4109 | Auto, the relay output works as a PID controller. Manual, the relay output has an On/Off ratio as set in the PI Manual setting. | R/W | Enum | 0 | |
ePWMFreqModeRelayC | 410B | Auto, the relay output works as a PID controller. Manual, the relay output has an On/Off ratio as set in the PI Manual setting. | R/W | Enum | 0 | |
Name | ID | Label | Description | Type | Access | Class |