Name ID Label Description Type Access Class
rMinimumSettingLoopB 405F LRV Loop B Lower Range Value Loop B. R/W Float 66
rMinimumSettingLoopC 423C LRV Loop C Lower Range Value Loop C. R/W Float 66
rMaximumSettingLoopA 4060 URV Loop A Upper Range Value Loop A. R/W Float 66
rMaximumSettingLoopB 4061 URV Loop B Upper Range Value Loop B. R/W Float 66
rMaximumSettingLoopC 423F URV Loop C Upper Range Value Loop C. R/W Float 66
rTransferValueLoopA 4240 Transfer Val Loop A Sets the transfer value. Range 3.0 to 23.0 mA (default 4.000). R/W Float 64
rTransferValueLoopB 4241 Transfer Val Loop B Sets the transfer value. Range 3.0 to 23.0 mA (default 4.000). R/W Float 64
rTransferValueLoopC 4242 Transfer Val Loop C Sets the transfer value. Range 3.0 to 23.0 mA (default 4.000). R/W Float 64
rOutputTestValueLoopA 4243 Test Value Loop A. R/W Float 64
rOutputTestValueLoopB 4244 Test Value Loop B. R/W Float 64
rOutputTestValueLoopC 4245 Test Value Loop C. R/W Float 64
rMinimumOutputLoopA 4238 LSL Loop A Lower Sensor Limit Loop A. R Float 32
rMinimumOutputLoopB 423A LSL Loop B Lower Sensor Limit Loop B. R Float 32
rMinimumOutputLoopC 423D LSL Loop C Lower Sensor Limit Loop C. R Float 32
rMaximumOutputLoopA 4239 USL Loop A Upper Sensor Limit Loop A. R Float 32
rMaximumOutputLoopB 423B USL Loop B Upper Sensor Limit Loop B. R Float 32
rMaximumOutputLoopC 423E USL Loop C Upper Sensor Limit Loop C. R Float 32
iHARTLowUnsignedIntegerIndex 4247 R/W Index 4096
eHARTErrorHoldMode 4249 Error Hold Mode Holds Outputs at last known value or switches to Transfer mode when sensor loses communication with controller. R/W Enum 2048
eMeasurementSelectLoopA 424A Meas. Select Loop A Selection list of sensor measurements. R Enum 2048
eMeasurementSelectLoopB 424B Meas. Select Loop B Selection list of sensor measurements. R Enum 2048
eMeasurementSelectLoopC 424C Meas. Select Loop C Selection list of sensor measurements. R Enum 2048
iFilterLoopA 4062 Filter Loop A Loop Filter Time Constant. R/W Integer 64
iFilterLoopB 4063 Filter Loop B Loop Filter Time Constant. R/W Integer 64
iFilterLoopC 424D Filter Loop C Loop Filter Time Constant. R/W Integer 64
iOutput4CalCountA 424E 4mA Cal Count A Output Loop 4mA calibration value in D/A counts. R/W Integer 64
iOutput4CalCountB 424F 4mA Cal Count B Output Loop 4mA calibration value in D/A counts. R/W Integer 64
iOutput4CalCountC 4250 4mA Cal Count C Output Loop 4mA calibration value in D/A counts. R/W Integer 64
iOutput20CalCountA 4251 20mA Cal Count A Output Loop 20mA calibration value in D/A counts. R/W Integer 64
iOutput20CalCountB 4252 20mA Cal Count B Output Loop 20mA calibration value in D/A counts. R/W Integer 64
iOutput20CalCountC 4253 20mA Cal Count C Output Loop 20mA calibration value in D/A counts. R/W Integer 64
eOutputTestEnableLoopA 4254 Test Enable Loop A R/W Enum 64
eOutputTestEnableLoopB 4255 Test Enable Loop B R/W Enum 64
eOutputTestEnableLoopC 4256 Test Enable Loop C R/W Enum 64
eUserHoldModeLoopA 4257 User Hold Loop A Selection List of user Hold Modes. R/W Enum 64
eUserHoldModeLoopB 4258 User Hold Loop B Selection List of user Hold Modes. R/W Enum 64
eUserHoldModeLoopC 4259 User Hold Loop C Selection List of user Hold Modes. R/W Enum 64
eUnitsOutputLoopA 425A Units Loop A Engineering Units Loop A. R Enum 8
eUnitsOutputLoopB 425B Units Loop B Engineering Units Loop B. R Enum 8
eUnitsOutputLoopC 425C Units Loop C Engineering Units Loop C. R Enum 8
eHARTModeA 4064 HART Loop A Mode HART Loop Modes. Fixed Current = 4 mA. Active Current = 4-20 mA. R/W Enum 64
eHARTModeB 4065 HART Loop B Mode HART Loop Modes. Fixed Current = 4 mA. Active Current = 4-20 mA. R/W Enum 64
iHARTAddressA 425D HART Loop A Address HART Loop Address (0-63) 0->Single Loop. R/W Integer 64
iHARTAddressB 425E HART Loop B Address HART Loop Address (0-63) 0->Single Loop. R/W Integer 64
eDeviceMappingRelayAtoSensor 40DF Mapping Relay A Status of Relay A mapping to HART sensor. R Enum 3
eDeviceMappingRelayBtoSensor 40E2 Mapping Relay B Status of Relay B mapping to HART sensor. R Enum 3
eDeviceMappingRelayCtoSensor 40E5 Mapping Relay C Status of Relay C mapping to HART sensor. R Enum 3
eDeviceMappingRelayDtoSensor 40E8 Mapping Relay D Status of Relay D mapping to HART sensor. R Enum 3
eDeviceMappingSC200Output1toSensor 40B2 Mapping Output 1 Status of sc200 Output 1 mapping to HART sensor. R Enum 3
eDeviceMappingSC200Output2toSensor 40B4 Mapping Output 2 Status of sc200 Output 2 mapping to HART sensor. R Enum 3
Name ID Label Description Type Access Class