Name ID Label Description Type Access Class
eTestRelayValueB 41A1 Test Relay B Value Sets the test state for Relay B. R/W Enum 4
eTestRelayValueC 41A2 Test Relay C Value Sets the test state for Relay C. R/W Enum 4
eTestRelayValueD 41A3 Test Relay D Value Sets the test state for Relay D. R/W Enum 4
eDiscreteInput1Mode 41A4 Discrete Input 1 Mode The Modes ON/High and OFF/Low are set by jumpers per the Instruction Manual. R/W Enum 1024
eDiscreteInput2Mode 41A5 Discrete Input 2 Mode The Modes ON/High and OFF/Low are set by jumpers per the Instruction Manual. R/W Enum 1024
eDiscreteInput3Mode 41A6 Discrete Input 3 Mode The Modes ON/High and OFF/Low are set by jumpers per the Instruction Manual. R/W Enum 1024
eDiscreteInput1WarnEnable 41A7 DI 1 Warning Enable When Enabled, a sc200 Warning will be generated when the Input is Active. R/W Enum 1024
eDiscreteInput2WarnEnable 41A8 DI 2 Warning Enable When Enabled, a sc200 Warning will be generated when the Input is Active. R/W Enum 1024
eDiscreteInput3WarnEnable 41A9 DI 3 Warning Enable When Enabled, a sc200 Warning will be generated when the Input is Active. R/W Enum 1024
eDiscreteInput1HoldMode 41AA DI 1 Hold Mode Selection list for the Discrete Input's Output Hold Mode. R/W Enum 1024
eDiscreteInput2HoldMode 41AB DI 2 Hold Mode Selection list for the Discrete Input's Output Hold Mode. R/W Enum 1024
eDiscreteInput3HoldMode 41AC DI 3 Hold Mode Selection list for the Discrete Input's Output Hold Mode. R/W Enum 1024
iDiscreteInput1OnDelay 41AD DI 1 On Delay (0-999) The delay in seconds before the Input goes Active. R/W Unsigned 1024
iDiscreteInput2OnDelay 41AE DI 2 On Delay (0-999) The delay in seconds before the Input goes Active. R/W Unsigned 1024
iDiscreteInput3OnDelay 41AF DI 3 On Delay (0-999) The delay in seconds before the Input goes Active. R/W Unsigned 1024
iDiscreteInput1OffDelay 41B0 DI 1 Off Delay (0-999) The delay in seconds before the Input goes Inactive. R/W Unsigned 1024
iDiscreteInput2OffDelay 41B1 DI 2 Off Delay (0-999) The delay in seconds before the Input goes Inactive. R/W Unsigned 1024
iDiscreteInput3OffDelay 41B2 DI 3 Off Delay (0-999) The delay in seconds before the Input goes Inactive. R/W Unsigned 1024
iOneLowUnsignedLongIntegerIndexSC200 41B5 R/W Index 4096
iNetworkModuleGoodMsg 41B7 Net Mod Good Msg Number of good messages on the network module. R Unsigned 1
iOneHighUnsignedLongIntegerIndexSC200 41B9 R/W Index 4096
iNetworkModuleStatsBadMsg 41BB Net Mod Bad Msg Number of bad messages on the Network Card Port. R Unsigned 1
iServicePortStatsGoodMsg 41BC Svc Port Good Msg Number of good messages on the Service Port. R Unsigned 1
iServicePortStatsBadMsg 41BD Svc Port Bad Msg Number of bad messages on the Service Port. R Unsigned 1
iPort1StatsGoodMsg 41BE Port 1 Good Msg Number of good messages on Port 1. R Unsigned 1
iPort1StatsBadMsg 41BF Port 1 Bad Msg Number of bad messages on Port 1. R Unsigned 1
iPort2StatsGoodMsg 41C0 Port 2 Good Msg Number of good messages on Port 2. R Unsigned 1
iPort2StatsBadMsg 41C1 Port 2 Bad Msg Number of bad messages on Port 2. R Unsigned 1
iPort3StatsGoodMsg 41C2 Port 3 Good Msg Number of good messages on Port 3. R Unsigned 1
iPort3StatsBadMsg 41C3 Port 3 Bad Msg Number of bad messages on Port 3. R Unsigned 1
iPort4StatsGoodMsg 41C4 Port 4 Good Msg Number of good messages on Port 4. R Unsigned 1
iPort4StatsBadMsg 41C5 Port 4 Bad Msg Number of bad messages on Port 4. R Unsigned 1
sMathUnits 41C7 Math Units Six character measurement unit for the sc200 Calculated Value. R ASCII 2048
sMathParameters 41C8 Math Parameters Six character measurement parameter for the sc200 Calculated Value. R ASCII 2048
sDigitalSensor1Connected 41DE Sensor 1 Status Sensor 1 Installation Status. R ASCII 4096
sDigitalSensor2Connected 41DF Sensor 2 Status Sensor 2 Installation Status R ASCII 4096
rLoop1Current 422A Loop 1 Current Corriente de lazo: Valor de la corriente de lazo tal como lo percibe el dispositivo. R/W Float 66
rLoop2Current 422B Loop 2 Current Corriente de lazo: Valor de la corriente de lazo tal como lo percibe el dispositivo. R/W Float 66
rLoopACurrent 4223 Loop A Current Corriente de lazo: Valor de la corriente de lazo tal como lo percibe el dispositivo. R/W Float 66
eLoopAAlarmCode 4224 Alarm A Select Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R Enum 64
bLoopAFlags 4225 Loop A Flags Analog Channel Flags- Defines the characteristics of the Analog Channel R/W BitEnum 64
rLoopBCurrent 4226 Loop B Current Corriente de lazo: Valor de la corriente de lazo tal como lo percibe el dispositivo. R/W Float 66
eLoopBAlarmCode 4227 Alarm B Select Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R Enum 64
bLoopBFlags 4228 Loop B Flags Analog Channel Flags- Defines the characteristics of the Analog Channel R BitEnum 64
rLoopCCurrent 4229 Loop C Current Corriente de lazo: Valor de la corriente de lazo tal como lo percibe el dispositivo. R/W Float 66
eLoopCAlarmCode 422F Alarm C Select Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R Enum 64
bLoopCFlags 4230 Loop C Flags Analog Channel Flags- Defines the characteristics of the Analog Channel R BitEnum 64
cAnalogChannelIndex 4231 R/W Index 4096
iHARTLowFloatIndex 4236 R/W Index 4096
rMinimumSettingLoopA 405E LRV Loop A Lower Range Value Loop A. R/W Float 66