Loading…
Name ID Label Description Type Access Class
rDeadbandControlD 40FD Sets the Controller Deadband/Proportional Band for Relay D. R/W Float 0
rSetpointEventA 40FE Setpoint Event A Sets the Event Controller Setpoint for Relay A. R/W Float 0
rSetpointEventB 40FF Setpoint Event B Sets the Event Controller Setpoint for Relay B. R/W Float 0
rSetpointEventC 4100 Setpoint Event C Sets the Event Controller Setpoint for Relay C. R/W Float 0
rSetpointEventD 4101 Setpoint Event D Sets the Event Controller Setpoint for Relay D. R/W Float 0
rDeadbandEventA 4102 Sets the Controller Deadband/Dead Zone for Relay B. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint. Dead Zone is a band around the setpoint. In this band the controller does not change the output signal. R/W Float 0
rDeadbandEventB 4103 Sets the Controller Deadband/Dead Zone for Relay B. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint. Dead Zone is a band around the setpoint. In this band the controller does not change the output signal R/W Float 0
rDeadbandEventC 4104 Sets the Controller Deadband/Dead Zone for Relay C. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint. Dead Zone is a band around the setpoint. In this band the controller does not change the output signal R/W Float 0
rDeadbandEventD 4105 Sets the Controller Deadband/Dead Zone for Relay D. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint. Dead Zone is a band around the setpoint. In this band the controller does not change the output signal R/W Float 0
rPIManualPWMA 4106 Manual Value A Sets the Manual control output level (%) Relay A. R/W Float 0
rPIManualPWMB 4108 Manual Value B Sets the Manual control output level (%) Relay B. R/W Float 0
rPIManualPWMC 410A Manual Value C Sets the Manual control output level (%) Relay C. R/W Float 0
rPIManualPWMD 410C Manual Value D Sets the Manual control output level (%) Relay D. R/W Float 0
rPIPeriodPWMA 410E Sets the period/pulse width for pwm/freq control Relay A. R/W Float 0
rPIPeriodPWMB 410F Sets the period/pulse width for pwm/freq control Relay B. R/W Float 0
rPIPeriodPWMC 4110 Sets the period/pulse width for pwm/freq control Relay C. R/W Float 0
rPIPeriodPWMD 4111 Sets the period/pulse width for pwm/freq control Relay 4. R/W Float 0
rPIMinWidthPulseA 4112 Sets the minimum pulse width for PWM in seconds (0.1 to Max Pulse Width) or sets the minimum number of pulses for Frequency control (0.001 to Max Number of Pulses) for Relay A. R/W Float 0
rPIMinWidthPulseB 4114 Sets the minimum pulse width for PWM in seconds (0.1 to Max Pulse Width) or sets the minimum number of pulses for Frequency control (0.001 to Max Number of Pulses) for Relay B. R/W Float 0
rPIMinWidthPulseC 4116 Sets the minimum pulse width for PWM in seconds (0.1 to Max Pulse Width) or sets the minimum number of pulses for Frequency control (0.001 to Max Number of Pulses) for Relay C. R/W Float 0
rPIMinWidthPulseD 4118 Sets the minimum pulse width for PWM in seconds (0.1 to Max Pulse Width) or sets the minimum number of pulses for Frequency control (0.001 to Max Number of Pulses) for Relay D. R/W Float 0
rPIMaxWidthPulseA 4113 Sets the maximum pulse width for PWM in seconds (Min Pulse Width to Period) or sets the maximum number of pulses for Frequency control (Min Number of Pulses to 60 ) for Relay A. R/W Float 0
rPIMaxWidthPulseB 4115 Sets the maximum pulse width for PWM in seconds (Min Pulse Width to Period) or sets the maximum number of pulses for Frequency control (Min Number of Pulses to 60 ) for Relay B. R/W Float 0
rPIMaxWidthPulseC 4117 Sets the maximum pulse width for PWM in seconds (Min Pulse Width to Period) or sets the maximum number of pulses for Frequency control (Min Number of Pulses to 60 ) for Relay C. R/W Float 0
rPIMaxWidthPulseD 4119 Sets the maximum pulse width for PWM in seconds (Min Pulse Width to Period) or sets the maximum number of pulses for Frequency control (Min Number of Pulses to 60 ) for Relay D. R/W Float 0
Name ID Label Description Type Access Class