Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
rPIDSetpoint1 | 40C5 | PID Setpt Out 1 | Sets the PID control setpoint for Output 1. | R/W | Float | 0 |
rPIDSetpoint2 | 40C6 | PID Setpt Out 2 | Sets the PID control setpoint for Output 2. | R/W | Float | 0 |
rPIDProportionalBand1 | 40C7 | PID Prop Band Out 1 | Sets the PID proportional band for Output 1. | R/W | Float | 0 |
rPIDProportionalBand2 | 40C8 | PID Prop Band Out 2 | Sets the PID proportional band for Output 2. | R/W | Float | 0 |
iOneLowUnsignedIntegerOutputIndexSC200 | 40CA | R/W | Index | 4096 | ||
eErrorHoldMode | 40CC | Error Hold Mode | Holds Outputs at last known value or switches to Transfer mode when sensor loses communication with controller. | R/W | Enum | 64 |
eMeasurementSelect1 | 40CD | Meas. Select Output 1 | Selection list of sensor measurements. | R | Enum | 64 |
eMeasurementSelect2 | 40CE | Meas. Select Output 2 | Selection list of sensor measurements. | R | Enum | 64 |
eType1 | 40B6 | Type Output 1 | Selection list of output modes. | R/W | Enum | 64 |
eType2 | 40B8 | Type Output 2 | Selection list of output modes. | R/W | Enum | 64 |
iFilter1 | 4069 | Filter Output 1 | Time constant Output 1. | R/W | Unsigned | 64 |
iFilter2 | 406A | Filter Output 2 | Time constant Output 2. | R/W | Unsigned | 64 |
eMinCurrentSelect1 | 4067 | 0/4 mA Sel Out 1 | Minimum current selection Output 1. | R/W | Enum | 64 |
eMinCurrentSelect2 | 4068 | 0/4 mA Sel Out 2 | Minimum current selection Output 2. | R/W | Enum | 64 |
ePIDMode1 | 40C2 | PID Mode Output 1 | Auto/Manual mode selection for Output 1. | R/W | Enum | 0 |
ePIDMode2 | 40C4 | PID Mode Output 2 | Auto/Manual mode selection for Output 2. | R/W | Enum | 0 |
ePIDPhase1 | 40CF | Phase Output 1 | Direct/Reverse phase selection Output 1. | R/W | Enum | 0 |
ePIDPhase2 | 40D0 | Phase Output 2 | Direct/Reverse phase selection Output 2. | R/W | Enum | 0 |
iPIDIntegralTime1 | 40D1 | PID Integral Out 1 | Integral time in seconds Output 1. | R/W | Unsigned | 0 |
iPIDIntegralTime2 | 40D2 | PID Integral Out 2 | Integral time in seconds Output 2. | R/W | Unsigned | 0 |
iPIDDerivativeTime1 | 40D3 | PID Derivative Out 1 | Derivative time in seconds Output 1. | R/W | Unsigned | 0 |
iPIDDerivativeTime2 | 40D4 | PID Derivative Out 2 | Derivative time in seconds Output 2. | R/W | Unsigned | 0 |
iPIDTransitTime1 | 40D5 | PID Transit Out 1 | Stops all PID control for a selected period of time. | R/W | Unsigned | 0 |
iPIDTransitTime2 | 40D6 | PID Transit Out 2 | Stops all PID control for a selected period of time. | R/W | Unsigned | 0 |
eRange1 | 40D7 | Range Output 1 | Selection List of sensor ranges. | R | Enum | 0 |
eRange2 | 40D8 | Range Output 2 | Selection List of sensor ranges. | R | Enum | 0 |
iOneLowFloatIndexSC200 | 40DC | R/W | Index | 4096 | ||
rHighAlarmAlarmA | 40DE | High Alarm A | Sets the High Alarm setpoint for Alarm A. | R/W | Float | 0 |
rHighAlarmAlarmB | 40E1 | High Alarm B | Sets the High Alarm setpoint for Alarm B. | R/W | Float | 0 |
rHighAlarmAlarmC | 40E4 | High Alarm C | Sets the High Alarm setpoint for Alarm C. | R/W | Float | 0 |
rHighAlarmAlarmD | 40E7 | High Alarm D | Sets the High Alarm setpoint for Alarm D. | R/W | Float | 0 |
rLowAlarmAlarmA | 40EA | Low Alarm A | Sets the Low Alarm setpoint for Alarm A. | R/W | Float | 0 |
rLowAlarmAlarmB | 40EB | Low Alarm B | Sets the Low Alarm setpoint for Alarm B. | R/W | Float | 0 |
rLowAlarmAlarmC | 40EC | Low Alarm C | Sets the Low Alarm setpoint for Alarm C. | R/W | Float | 0 |
rLowAlarmAlarmD | 40ED | Low Alarm D | Sets the Low Alarm setpoint for Alarm D. | R/W | Float | 0 |
rHighDeadbandAlarmA | 40EE | High Deadband A | Sets the High Alarm deadband for Alarm A. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint | R/W | Float | 0 |
rHighDeadbandAlarmB | 40EF | High Deadband B | Sets the High Alarm deadband for Alarm B. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint | R/W | Float | 0 |
rHighDeadbandAlarmC | 40F0 | High Deadband C | Sets the High Alarm deadband for Alarm C. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint | R/W | Float | 0 |
rHighDeadbandAlarmD | 40F1 | High Deadband D | Sets the High Alarm deadband for Alarm D. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint | R/W | Float | 0 |
rLowDeadbandAlarmA | 40F2 | Low Deadband A | Sets the Low Alarm deadband for Alarm A. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint | R/W | Float | 0 |
rLowDeadbandAlarmB | 40F3 | Low Deadband B | Sets the Low Alarm deadband for Alarm B. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint | R/W | Float | 0 |
rLowDeadbandAlarmC | 40F4 | Low Deadband C | Sets the Low Alarm deadband for Alarm C. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint | R/W | Float | 0 |
rLowDeadbandAlarmD | 40F5 | Low Deadband D | Sets the Low Alarm deadband for Alarm D. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint | R/W | Float | 0 |
rSetpointControlA | 40F6 | Setpoint Control A | Sets the Controller Setpoint for Relay A. | R/W | Float | 0 |
rSetpointControlB | 40F7 | Setpoint Control B | Sets the Controller Setpoint for Relay B. | R/W | Float | 0 |
rSetpointControlC | 40F8 | Setpoint Control C | Sets the Controller Setpoint for Relay C. | R/W | Float | 0 |
rSetpointControlD | 40F9 | Setpoint Control D | Sets the Controller Setpoint for Relay D. | R/W | Float | 0 |
rDeadbandControlA | 40FA | Sets the Controller Deadband/Proportional Band for Relay A. | R/W | Float | 0 | |
rDeadbandControlB | 40FB | Sets the Controller Deadband/Proportional Band for Relay B. | R/W | Float | 0 | |
rDeadbandControlC | 40FC | Sets the Controller Deadband/Proportional Band for Relay C. | R/W | Float | 0 | |