Name ID Label Description Type Access Class
bConfigFlags1_ProtectLimits 403F Allow Override Limits Allow diag. and self-tune to override limits. R/W Enum 8
bConfigFlags1_LowerLimit 403B Pos Lower Limit Enable To enable or disable position lower limit. R/W Enum 8
bConfigFlags1_UpperLimit 403D Pos Upper Limit Enable To enable or disable position upper limit. R/W Enum 8
bConfigFlags1_TightShutoff 4038 Tight Shutoff Tight Shutoff Limit- Threshold for tight shutoff: when selected, if the input signal would position the valve below the tight shutoff value, full supply or atmosphere pressure is supplied to the actuator to close the valve with full seating force. Set the TS value between -1% and 20%, then enable the TS function. R/W Enum 8
bConfigFlags1_Characterization 403A Characterization Cam Configuration Flags- cam used - defines relationship between flow capacity (Cv) and percentage opening of the valve. Several cams are available: linear; =%50; =%30; quick opening coefficient of 50; custom; CamFlex=%. R/W Enum 8
bConfigFlags2 4005 Local Buttons Button Configuration Flags- Defines lock level for SVI3 buttons to avoid unintended modifications. R/W Enum 8
bConfigFlags3 41D2 Setpoint Mode Setup Configuration Flags- These options determine whether the controller setpoint will be in local, local only, remote or last mode on startup. R/W Enum 8
fTSLimit 4039 Tight Shutoff Value Tight Shutoff Limit- Threshold for tight shutoff: when selected, if the input signal would position the valve below the tight shutoff value, full supply or atmosphere pressure is supplied to the actuator to close the valve with full seating force. Value between -1% and 20% and not to include. R/W Float 8
fLowerPosLimits 403C Lower Limit Lower Position Limit- The SVI3 allows the user to establish software limit stops. The control functions will NOT allow the valve position to be lower than the lower position limit. However this option DOES NOT PROVIDE MECHANICAL STOPS for the valve. During an electrical or an air failure the valve will go to the failsafe position without regard to the software limit stops. The manual position full closed or full open will similarly ignore limit stops. The value should be set between -10 and 50.0 not to include R/W Float 8
fUpperPosLimits 403E Upper Limit Upper Position Limit- The SVI3 allows the user to establish software limit stops. The control functions will NOT allow the valve position to be above than the upper position limit.However this option DOES NOT PROVIDE MECHANICAL STOPS for the valve. During an electrical or an air failure the valve will go to the failsafe position without regard to the software limit stops. The manual position full closed or full open will similarly ignore limit stops. R/W Float 8
Name ID Label Description Type Access Class