Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
fSwitch1Value | 4079 | DO Switch 1 Value | The value is set for Position Low / Upper Limits.( Switch 1 Value must be between 0 and 199.99. ) Attention: This is valid under the condition of switch 1 type is Posistion Low/High Limit ), but to some host, like SDC-625, to activate this field maybe need to close / open this page again. | R/W | Float | 8 |
fSwitch2Value | 407C | DO Switch 2 Value | The value is set for Position Low / Upper Limits.( Switch 2 Value must be between 0 and 199.99. ) Attention: This is valid under the condition of switch 2 type is Posistion Low/High Limit, but to some host, like SDC-625, to activate this field maybe need to close / open this page again. | R/W | Float | 8 |
cSwitchInType | 410C | DI Switch Status | Digital Input Switch is enabled or disabled. | R/W | Enum | 8 |
cMode_l | 40E7 | Mode(local) | W | Enum | 4096 | |
bFaultCode0 | 4039 | Fault Code 0 | Reports Device Errors | R | BitEnum | 19 |
bFaultCode1 | 403A | Fault Code 1 | Reports Device Errors | R | BitEnum | 19 |
bFaultCode2 | 403B | Fault Code 2 | Reports Device Errors | R | BitEnum | 19 |
bFaultCode3 | 403C | Fault Code 3 | Reports Device Errors | R | BitEnum | 19 |
bFaultCode4 | 403D | Fault Code 4 | Reports Device Errors | R | BitEnum | 19 |
bFaultCode5 | 403E | Fault Code 5 | Reports Device Errors | R | BitEnum | 19 |
Name | ID | Label | Description | Type | Access | Class |