Loading…
Name ID Label Description Type Access Class
write_device_variable_codes 07FD R/W Enum 4096
device_variable_family_codes 0801 R/W Enum 4096
device_variable_classification_codes 07FB R/W Enum 4096
trim_point_codes 07FF R/W Enum 4096
capture_mode_codes 0803 R/W Enum 4096
physical_layer_type_codes 0800 R/W Enum 4096
lock_device_status_codes 07FE R/W Enum 4096
analog_channel_flags 0802 R/W Enum 4096
analog_channel_saturated_codes 08D6 R/W Enum 4096
analog_channel_fixed_codes 08D7 R/W Enum 4096
standardized_status_0_codes 08C1 R/W Enum 4096
standardized_status_1_codes 08C2 R/W Enum 4096
standardized_status_2_codes 08C3 R/W Enum 4096
standardized_status_3_codes 08C4 R/W Enum 4096
device_variable_code_codes 08C6 R/W Enum 4096
time_set_codes 08CA R/W Enum 4096
real_time_clock_flag_codes 08CB R/W Enum 4096
si_control_codes 08CF R/W Enum 4096
device_profile_codes 08D1 Device Profile R/W Enum 4096
process_data_status 0804 R/W Enum 4096
limit_status 0805 R/W Enum 4096
device_family_status 0806 R/W Enum 4096
manufacturer_id 0099 Fabricante Código de identificación del fabricante: Hace referencia a un fabricante específico y suele ser el nombre de la empresa responsable de la fabricación de este dispositivo de campo. R Enum 128
private_label_distributor 00A8 Distribuidor Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers R Enum 2048
device_type 009A Model Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer R Enum 128
write_protect 00A7 Write protect Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. R/W Enum 2
physical_signaling_code 00AB Physicl signl code Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port R Enum 2048
operatingMode 0870 Operate mode 1 Field Device Specific Operating Mode 1- A possible mode of operation in Field Device R Enum 2049
loop_current_mode 0808 Loop current mode Modo de corriente de lazo: Indica si la corriente de lazo es activa o fija (es decir, el dispositivo está en derivaciones múltiples). R/W Enum 64
device_flags 00A0 Dev flags Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer R BitEnum 2048
device_profile 00FF Device Profile R Enum 2048
country_code_codes 08D3 R/W Enum 4096
master_mode_code 08D5 R/W Enum 4096
extended_fld_device_status 0807 Ext dev status Extended Field Device Status- This provides additional Device Status information R BitEnum 131
standardized_status_0 0104 Device Diagnostic Status 0 R BitEnum 131
standardized_status_1 0105 Device Diagnostic Status 1 R BitEnum 131
standardized_status_2 0106 I/O and Subdevice Status R BitEnum 131
standardized_status_3 0107 WirelessHART Status R BitEnum 131
analog_channel_saturated1 103D AO saturated Field Device Specific Dynamic Variable Analog Output Saturated- Data that indicates which of the Analog Outputs are, or are not, saturated. The analog and digital Analog Outputs for the Dynamic Variable are beyond their limits and no longer represent the true applied process. R BitEnum 2051
analog_channel_fixed1 1040 AO fixed Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process. R BitEnum 2051
time_set 1157 Time Set Option W Enum 2052
real_time_clock_flag 115C Real Time Clock Flags R BitEnum 2050
country_code 1259 Country Country of intended device installation R/W Enum 2048
si_control 125A SI Unit Control Indicates if device should only display SI unit codes R/W Enum 2048
burst_trigger_units 1267 Burst Trigger Units R/W Enum 16
burst_mode_control_code 07F0 R/W Enum 4096
burst_trigger_classification 1266 Burst Trigger Class R/W Enum 16
burst_message_trigger_mode_codes 08C5 R/W Enum 4096
event_nofication_control_codes 08C7 R/W Enum 4096
event_status_codes 08C8 R/W Enum 4096
Name ID Label Description Type Access Class