Loading…
Name ID Label Description Type Access Class
pressure_upper_range_value 1396 URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Float 32
pressure_lower_range_value 1397 LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Float 32
pressure_damping_value 1398 圧力ダンピング Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Float 8
flange_type 139A フランジ タイプ Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Enum 2048
o_ring_material 139B O リング材質 O Ring Material- Construction material of a seal that exists between the module and flange. R/W Enum 2048
meter_installation 139C メーター タイプ Meter Installation- Defines whether there is a meter installed or not and possibly what information the meter will display. R/W Enum 256
remote_seal_type 139D リモート タイプ Remote Seal Type- Type of device that is capable of detecting and passing on the process pressure on to the module. This is only unambiguous if 1 remote seal is installed. R/W Enum 2048
module_fill_fluid 139E 封入液 Sensor Fill Fluid- Fluid material in the module. R Enum 2048
number_of_remote_seals 139F リモート数量 Number of Remote Seals- Physical quantity of the seals for the remote seal that is installed. R/W Enum 2048
analog_output_value 1779 PV AO Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes. Analog Output- Measureable physical output which changes with respect to time, without user intervention. R/W Float 66
Name ID Label Description Type Access Class