Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
remote_seal_fill_fluid | 400D | RS fill fluid | Remote Seal Fill Fluid- Fluid material in the device remote seal. | R/W | Enum | 2048 |
module_range_code | 4000 | Module rnge | Module range- pressure range located on the side of the sensor | R | Enum | 2048 |
temperature_value | 4001 | Amp temp | Field Device Variable Value- Digital value that changes with respect to process or ambient temperature over time with no user intervention. Sensor Temperature- Temperature associated with the sensor that is responsible for a process measurement. | R | Float | 10 |
temperature_units | 4018 | Amp temp unit | Field Device Variable Unit- Digital unit that the variable will be displayed with. Sensor Temperature- Temperature associated with the sensor that is responsible for a process measurement. | R | Enum | 8 |
upper_display_value | 401C | UDV | XMTR LCD- Transmitter LCD display parameter. XMTR LCD Display is able to set in independence with Analog Output. UDV: Upper Disp Value- Available range is as below; -99999 to 99999 -9999.9 to 9999.9 -999.99 to 999.99 -99.999 to 99.999 -9.9999 to 9.9999 | R/W | Float | 256 |
lower_display_value | 401D | LDV | XMTR LCD- Transmitter LCD display parameter. XMTR LCD Display is able to set in independence with Analog Output. LDV: Lower Disp Value- Available range is as below; -99999 to 99999 -9999.9 to 9999.9 -999.99 to 999.99 -99.999 to 99.999 -9.9999 to 9.9999 | R/W | Float | 256 |
digit_number_under_decimal_point | 401E | Digit_DP | XMTR LCD- Transmitter LCD display parameter. XMTR LCD Display is able to set in independence with Analog Output. Digit_DP: Digit under Decimal Point- Available range is from 0 to 4 as below; 0 (XXXXX) 1 (XXXX.X) 2 (XXX.XX) 3 (XX.XXX) 4 (X.XXXX) | R/W | Unsigned | 256 |
unit_code | 401F | LCD_Unit | XMTR LCD- Transmitter LCD display parameter. XMTR LCD Display is able to set in independence with Analog Output. There are 4 groups as below. All units appear in series. 1)Pressure(DISP=LIN)2)Level(DISP=LIN) 3)Flow(DISP=SQR) 4)Special(%and None) | R/W | Enum | 256 |
option | 4020 | LCD_Opt. | XMTR LCD- Transmitter LCD display parameter. XMTR LCD Display is able to set in independence with Analog Output. LCD_Opt.: AZ_LCD_Option is not used now. | R/W | Unsigned | 256 |
Cut_Point_value | 4005 | Cut_Pt % | Cut_Pt: Low Cut Point- Dimension in % Flow at Calibrated Range, affects Analog Output and Transmitter LCD in SQR mode only. Available range is from 0% to 20% Flow. | R/W | Float | 16 |
Cut_Mode_value | 4006 | Cut_Mode | Cut_Mode: Low Cut Mode- Output mode below Low Cut Point, affects Analog Output and Transmitter LCD in SQR mode only. Available mode is LINEAR or ZERO. | R/W | Enum | 16 |
burnout_current_overscale | 4027 | Overscale | Overscale_Current is able to set in the range from 20.8mA to 21.6mA. | R/W | Enum | 16 |
burnout_current_underscale | 4028 | Underscale | Underscale_Current is able to set in the range from 3.2mA to 3.8mA. | R/W | Enum | 16 |
cell_body_no | 400C | Cell B/N | Cell B/N: Cell_Body_No- Manufacturer Cell Body Number consist of 8 digits(max.), read only. | R | PackedAscii | 2048 |
model_code | 4014 | Model_Code | Model Code- Manufacturer Model Code consist of 16 digits(max.) not including hyphen. | R/W | PackedAscii | 2048 |
serial_number | 4015 | Ser-No | Ser-No: Serial_Number- Manufacturer Serial Number consist of 8 digits(max.), read only. | R | PackedAscii | 2048 |
unique_device_type_code | 07ED | R/W | Enum | 128 | ||
rosemount_model_code | 07F5 | R/W | Enum | 2048 | ||
rosemount_analytical_model_code | 07F6 | R/W | Enum | 2048 | ||
kayray_model_code | 07F7 | R/W | Enum | 2048 | ||
micro_motion_model_code | 07F8 | R/W | Enum | 2048 | ||
units_code | 07E9 | R/W | Enum | 4096 | ||
transfer_function_code | 07EA | R/W | Enum | 4096 | ||
material_code | 07EC | R/W | Enum | 4096 | ||
alarm_selection_code | 07EB | R/W | Enum | 4096 | ||
write_protect_code | 07EE | R/W | Enum | 2048 | ||
company_identification_code | 07EF | R/W | Enum | 128 | ||
burst_mode_control_code | 07F0 | R/W | Enum | 128 | ||
physical_signaling_codes | 07F1 | R/W | Enum | 2048 | ||
flag_assignment | 07F2 | R/W | Enum | 128 | ||
operating_mode_code | 07F3 | R/W | Enum | 2048 | ||
analog_output_numbers_code | 07F4 | R/W | Enum | 4096 | ||
response_code | 0096 | Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. | R/W | Enum | 129 | |
comm_status | 0098 | Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. | R/W | BitEnum | 131 | |
device_status | 0097 | Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process | R/W | BitEnum | 131 | |
manufacturer_id | 0099 | Manufacturer | Manufacturer Identification Code- References a specific manufacturer, which is usually a company name, that is responsible for the manufacture of this Field Device. | R | Enum | 128 |
device_type | 009A | Model | Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer | R | Enum | 128 |
request_preambles | 009B | Num req preams | Number of Request Preambles- Number of Preambles required from the Host request by the Field Device | R | Unsigned | 128 |
universal_revision | 009C | Universal rev | Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to | R | Unsigned | 128 |
transmitter_revision | 009D | Fld dev rev | Field Device Revision- Revision of the Field Device Specific Device Description, that the Field Device conforms to | R | Unsigned | 128 |
software_revision | 009E | Software rev | Field Device Software Revision- This revision corresponds to the software or firmware, that is embedded in the Field Device | R | Unsigned | 2048 |
hardware_revision | 009F | Hardware rev | Hardware Revision- Revision that corresponds to the electronics hardware of the Field Device. | R | Unsigned | 2048 |
physical_signaling_code | 00AB | Physicl signl code | Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port | R | Enum | 2048 |
device_flags | 00A0 | Dev flags | Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer | R | BitEnum | 128 |
device_id | 00A1 | Dev id | Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. | R | Unsigned | 128 |
polling_address | 00A2 | Poll addr | Polling Address- Address used by the Host to identify a Field Device, and changeable by the User to control: the Multidrop Mode for Analog Output 1), and the Analog Output Fixed Mode of Analog Output 1) | W | Unsigned | 128 |
tag | 00A3 | Tag | Tag- Text that is associated with the Field Device installation. This text can be used by the user in any way. A recommended use is as a unique label to a plant that correlates to a Field Device label: a plant drawing, or on a Control System. This variable is also used as a type of data link layer address handle. | R/W | PackedAscii | 2048 |
message | 00A4 | Message | Message- Text that is associated with the Field Device. This text can be used by the user in any way. There is no recommended use. | R/W | PackedAscii | 2048 |
descriptor | 00A5 | Descriptor | Descriptor- Text that is associated with the Field Device. This text can be used by the user in any way. There is no specific recommended use. | R/W | PackedAscii | 2048 |
date | 00A6 | Date | Date- Gregorian calendar date that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. | R/W | HartDate | 2048 |
Name | ID | Label | Description | Type | Access | Class |