Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
sDeviceSwVersion | 4040 | Device SW Version | R | ASCII | 0 | |
eHARTFlowUnits | 4043 | HART Flow Units | R/W | Enum | 8 | |
eHARTTemperatureUnits | 4044 | HART Temp. Units | R/W | Enum | 8 | |
eHARTTotalUnits | 4045 | HART Total Units | R/W | Enum | 8 | |
rPlenumWidth | 4048 | Plenum Width (Diameter) Value | R/W | Float | 0 | |
rPlenumHeight | 4049 | Plenum Height Value | Plenum Height Value | R/W | Float | 0 |
eHARTPlenumUnit | 404A | Plenum Unit | R | Enum | 0 | |
rFlowLowerLimit | 4010 | Flow Lower Limit | Flow Lower Limit Value | R | Float | 0 |
rFlowUpperLimit | 400F | Flow Upper Limit | Flow Upper Limit Value | R | Float | 0 |
rTemperatureLowerLimit | 4033 | Temp Lower Limit | Temp Lower Limit Value | R/W | Float | 0 |
rTemperatureUpperLimit | 4032 | Temp Upper Limit | Temp Upper Limit Value | R/W | Float | 0 |
rKFactor1 | 404F | K Factor 1 | K Factor 1 Value | R/W | Float | 0 |
rKFactor2 | 4050 | K Factor 2 | K Factor 2 Value | R/W | Float | 0 |
rKFactor3 | 4051 | K Factor 3 | K Factor 3 Value | R/W | Float | 0 |
rKFactor4 | 4052 | K Factor 4 | K Factor 4 Value | R/W | Float | 0 |
eFactoryReset | 4055 | Factory Reset | W | Enum | 0 | |
eSecondaryOutputMode | 4057 | Secondary Output Mode | R/W | Enum | 10 | |
device_status | 0097 | Device status | Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process | R | BitEnum | 131 |
units_code | 07E9 | R/W | Enum | 4096 | ||
transfer_function_code | 07EA | R/W | Enum | 4096 | ||
material_code | 07EC | R/W | Enum | 4096 | ||
alarm_selection_code | 07EB | R/W | Enum | 4096 | ||
write_protect_code | 07EE | R/W | Enum | 4096 | ||
company_identification_code | 07EF | R/W | Enum | 4096 | ||
physical_signaling_codes | 07F1 | R/W | Enum | 4096 | ||
Name | ID | Label | Description | Type | Access | Class |