Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
eMassLS | 4026 | Mass LS | R | Enum | 10 | |
eMassStatus | 4027 | Totalizer LSL | R | BitEnum | 10 | |
rVelocityFlowValue | 402B | Velocity Flow Value | R | Float | 10 | |
eVelocityFlowUnits | 402A | Flow Value Unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 10 |
eVelocityFlowClassification | 402F | Flow Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
eVelocityFlowPDQ | 402C | Flow PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 10 |
eVelocityFlowLS | 402D | Flow LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 10 |
eVelocityFlowStatus | 402E | Flow Fmly stat | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 10 |
rTemperatureValue | 4031 | Temperature | Sensor Temperature- Temperature of the sensor that is making the process measurement | R | Float | 10 |
eTemperatureUnits | 4030 | Snsr temp unit | Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. | R | Enum | 8 |
Name | ID | Label | Description | Type | Access | Class |