Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
rFlowMinimumSpan | 4006 | Flow minimum span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 0 |
rFlowDampingValue | 4007 | Flo damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R | Float | 0 |
cFlowSerialNumber | 4008 | Flow serial number | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 2048 |
rTotalMinimumSpan | 4009 | Flow minimum span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 0 |
rTotalDampingValue | 400A | Flo damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R | Float | 0 |
rTotalUpperLimit | 400B | USL | R | Float | 0 | |
rTotalLowerLimit | 400C | LSL | R | Float | 0 | |
rVolumeFlowValue | 400E | Flow Value | R | Float | 10 | |
eVolumeFlowUnits | 400D | Flow Value Unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 10 |
eVolumeFlowClassification | 4014 | Flow Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
eVolumeFlowPDQ | 4011 | Flow PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 1 |
eVolumeFlowLS | 4012 | Flow LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 1 |
eVolumeFlowStatus | 4013 | Flow Fmly stat | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 1 |
rTotalValue | 4016 | R | Float | 10 | ||
lRolloverValue | 4017 | Total Rollover | Total Rollover Value | R | Unsigned | 10 |
eTotalUnits | 4015 | Total Units | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R | Enum | 10 |
eVolumeFamily | 401E | Device family | R | Enum | 2048 | |
eVolumeClassification | 401C | Totalizer Class | R | Enum | 0 | |
eVolumePDQ | 4019 | Volume PDQ | R | Enum | 10 | |
eVolumeLS | 401A | Volume LS | R | Enum | 10 | |
eVolumeStatus | 401B | Volume LSL | R | BitEnum | 10 | |
rMassFlowValue | 4020 | Flow Value | R | Float | 10 | |
eMassFlowUnits | 401F | Flow Value Unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 10 |
eMassFlowClassification | 4024 | Flow Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
eMassFlowPDQ | 4021 | Flow PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 10 |
Name | ID | Label | Description | Type | Access | Class |