Loading…
Name ID Label Description Type Access Class
rFlowMinimumSpan 4006 Flow minimum span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
rFlowDampingValue 4007 Flo damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R Float 0
cFlowSerialNumber 4008 Flow serial number Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R Unsigned 2048
rTotalMinimumSpan 4009 Flow minimum span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
rTotalDampingValue 400A Flo damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R Float 0
rTotalUpperLimit 400B USL R Float 0
rTotalLowerLimit 400C LSL R Float 0
rVolumeFlowValue 400E Flow Value R Float 10
eVolumeFlowUnits 400D Flow Value Unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 10
eVolumeFlowClassification 4014 Flow Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
eVolumeFlowPDQ 4011 Flow PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 1
eVolumeFlowLS 4012 Flow LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 1
eVolumeFlowStatus 4013 Flow Fmly stat Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 1
rTotalValue 4016 R Float 10
lRolloverValue 4017 Total Rollover Total Rollover Value R Unsigned 10
eTotalUnits 4015 Total Units Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R Enum 10
eVolumeFamily 401E Device family R Enum 2048
eVolumeClassification 401C Totalizer Class R Enum 0
eVolumePDQ 4019 Volume PDQ R Enum 10
eVolumeLS 401A Volume LS R Enum 10
eVolumeStatus 401B Volume LSL R BitEnum 10
rMassFlowValue 4020 Flow Value R Float 10
eMassFlowUnits 401F Flow Value Unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 10
eMassFlowClassification 4024 Flow Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
eMassFlowPDQ 4021 Flow PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 10
Name ID Label Description Type Access Class