Loading…
Name ID Label Description Type Access Class
analog_in 4029 Analog Input Displays the input current of the 4-20 mA loop. R Float 2050
analog_in_limit_status 4587 LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 10
analog_in_quality 4588 PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 10
analog_in_class 4589 Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 2048
analog_in_family_status 458A Family status Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 10
press_A 4031 Pressure A Displays the output pressure from Port A of the instrument. R Float 2050
press_units 4032 Pressure Units Units of Pressure. Supported units are psi, kPA, bar, or kg/cm2. R/W Enum 2048
press_A_limit_status 458B LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 10
press_A_quality 458C PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 10
press_A_class 458D Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 2048
Name ID Label Description Type Access Class