Loading…
Name ID Label Description Type Access Class
CO_Input20mA_2 41B0 20 mA value Enter 20 mA value R/W Float 2048
Unit_Variable_CO_Input20mA_2 41B1 R Enum 2048
CO_InputSelector_1 4199 Assign curr. 1 Select process variable for current output R/W Enum 2048
CO_InputSelector_2 419C Assign curr. 2 Select process variable for current output R/W Enum 2048
CO_InputSelOffVisible_1 41B4 InputSelOffVisible 1 R Unsigned 2048
CO_InputSelOffVisible_2 41B5 InputSelOffVisible 1 R Unsigned 2048
CO_MeasuredValue_1 41B6 Measur. curr. 1 Shows the current value of the current output which is currently measured R Float 2
CO_MeasuredValue_2 41B7 Measur. curr. 2 Shows the current value of the current output which is currently measured R Float 2
CO_OperatingMode_1 419A Current span Select current range for process value output and upper/lower level for alarm signal R/W Enum 2048
CO_OperatingMode_2 419D Current span Select current range for process value output and upper/lower level for alarm signal R/W Enum 2048
Name ID Label Description Type Access Class