Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
C4W_ConcentrationCoefficientA3_1 | 402C | A3 | Enter the coefficient | R/W | Float | 2048 |
C4W_ConcentrationCoefficientA4_1 | 402D | A4 | Enter the coefficient | R/W | Float | 2048 |
C4W_ConcentrationCoefficientB1_1 | 402E | B1 | Enter the coefficient | R/W | Float | 2048 |
C4W_ConcentrationCoefficientB2_1 | 402F | B2 | Enter the coefficient | R/W | Float | 2048 |
C4W_ConcentrationCoefficientB3_1 | 4030 | B3 | Enter the coefficient | R/W | Float | 2048 |
C4W_Damping_ArrayElement_1_1 | 4031 | Oscillation damping 0 | Shows the current oscillation damping. The oscillation damping is an indicator of the sensor's current need for excitation power. | R | Float | 2 |
C4W_Damping_ArrayElement_2_1 | 4032 | Oscillation damping 1 | Shows the current oscillation damping. The oscillation damping is an indicator of the sensor's current need for excitation power. | R | Float | 2 |
C4W_DampingMax_1 | 4033 | Maximum damping partial filled pipe det. | R/W | Float | 2048 | |
C4W_DensityAdjustControl_1 | 4035 | Execute density adjustment | Select the next step to be performed for the density adjustment | R/W | Enum | 2048 |
C4W_DensityAdjustFactor_1 | 4039 | Density adjustment factor | Shows the calculated correction factor for the density | R | Float | 2048 |