Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
Unit_Variable_DISP_Value03_100Percent_1 | 409C | R | Enum | 2048 | ||
FLOW_ConductivityTempCoeff_1 | 409F | Conductivity temperature coefficient | R/W | Float | 2048 | |
FLOW_DensityForcing_1 | 40A0 | Density calculation | R/W | Enum | 2048 | |
FLOW_FlowMonitoringSelector_1 | 40A1 | Assign process variable | Select process variable for low flow cut off | R/W | Enum | 2048 |
FLOW_In3DampingTime_1 | 40A2 | Conductivity damping | R/W | Float | 2048 | |
FLOW_In5DampingTime_1 | 40A3 | Temperature damping | R/W | Float | 2048 | |
FLOW_InstallationDirection_1 | 40A4 | Installation direction | Set sign of flow direction to match the direction of the arrow on the sensor | R/W | Enum | 2048 |
FLOW_LinearExpansionCoeff_1 | 40A5 | Linear expansion coefficient | Enter linear, medium-specific expansion coefficient for calculating the reference density | R/W | Float | 2048 |
FLOW_LowFlowHysteresis_1 | 40A6 | Off value low flow cutoff | Enter off value for low flow cut off | R/W | Float | 2048 |
FLOW_LowFlowLimit_1 | 40A7 | On value low flow cutoff | Enter on value for low flow cut off | R/W | Float | 2048 |
Name | ID | Label | Description | Type | Access | Class |