名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
flow_range_status | 400E | Active Range | Range Status - Indicates the active range if in dual range mode. | 读 | 枚举 | 34 |
current_range | 400F | Current Span | Current Span - always 4-20 mA with HART, max. output current can be either 25 mA or 20.5 mA. | 读/写 | 枚举 | 64 |
flow_alarm_type | 4010 | Alarm Type | Analog Output Alarm Type - Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE - The Digital Value representation may not be determinate. | 读/写 | 枚举 | 64 |
analog_simulation_select | 4011 | Analog Sim | Analog Simulation - Simulates the specified analog output current. | 读/写 | 枚举 | 32 |
freq_pulse_switch | 4003 | Freq/Pulse | Frequency/Pulse - Controls the operation mode of the frequency and pulse output. Freq: Flow / frequency. Pulse: Volume / pulse. | 读/写 | 枚举 | 32 |
max_pulse_width | 4013 | 脉冲宽度 | Pulse width - Maximum width of each pulse of the pulse output. | 读/写 | 浮点 | 512 |
frequency_full_scale_value | 4014 | Max Freq | Maximum Frequency - Full scale frequency for the upper range limit flow. | 读/写 | 整型 | 512 |
frequency_upper_range_limit | 4015 | URV | Upper Range Value - Flow value at maximum frequency. | 读/写 | 浮点 | 512 |
freq_output_config | 4016 | Output | Output - The frequency/pulse output can generate positive or negative pulses in active (push-pull) or passive (open-collector) mode. | 读/写 | 枚举 | 32 |
freq_alarm_select | 4017 | FO Alarm Type | Frequency output alarm type - Status of frequency/pulse output in error condition. | 读/写 | 枚举 | 32 |
名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |