Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
ConstAnalog_ActInstance | 4000 | R/W | Unsigned | 32 | ||
ConstDigital_ActInstance | 4001 | R/W | Unsigned | 32 | ||
CurrentOutput_ActInstance | 4002 | R/W | Unsigned | 32 | ||
CO_AdjustMode_1 | 4003 | Trim | R/W | Enum | 0 | |
CO_AdjustMode_2 | 4006 | Trim | R/W | Enum | 0 | |
CO_FailsafeMode_1 | 4007 | Failure mode (34) | Select alarm condition for current output value | R/W | Enum | 0 |
CO_FailsafeMode_2 | 4009 | Failure mode (34) | Select alarm condition for current output value | R/W | Enum | 0 |
CO_FailsafeValue_1 | 400B | Failure current (35) | Set current output value for alarm condition | R/W | Float | 0 |
CO_FailsafeValue_2 | 400C | Failure current (35) | Set current output value for alarm condition | R/W | Float | 0 |
CO_FixedValue_1 | 400D | Fixed current (33) | R/W | Float | 0 | |
CO_FixedValue_2 | 400E | Fixed current (33) | R/W | Float | 0 | |
CO_Input04mA_1 | 400F | 4 mA value | Enter 4 mA value | R/W | Float | 0 |
CO_Input04mA_2 | 4018 | 4 mA value | Enter 4 mA value | R/W | Float | 0 |
CO_Input20mA_1 | 401C | 20 mA value | Enter 20 mA value | R/W | Float | 0 |
CO_Input20mA_2 | 401E | 20 mA value | Enter 20 mA value | R/W | Float | 0 |
CO_InputSelector_1 | 4011 | Assign curr. | Select process variable for current output | R/W | Enum | 0 |
CO_InputSelector_2 | 401A | Assign curr. | Select process variable for current output | R/W | Enum | 0 |
CO_MeasuredValue_1 | 4020 | Measur. curr. 1 | R | Float | 2 | |
CO_MeasuredValue_2 | 4021 | Measur. curr. 2 | R | Float | 2 | |
CO_MeasuringMode_1 | 4022 | Measuring mode | R/W | Enum | 0 | |
CO_MeasuringMode_2 | 4023 | Measuring mode | R/W | Enum | 0 | |
CO_OperatingMode_1 | 4008 | Current span (32) | Select current range for process value output and upper/lower level for alarm signal | R/W | Enum | 0 |
CO_OperatingMode_2 | 400A | Current span (32) | Select current range for process value output and upper/lower level for alarm signal | R/W | Enum | 0 |
CO_OutStatus_1 | 4024 | Status | R | Unsigned | 2 | |
CO_OutStatus_2 | 4025 | Status | R | Unsigned | 2 | |
CO_OutValue_1 | 4026 | Output curr. 1 | R | Float | 2 | |
CO_OutValue_2 | 4027 | Output curr. 2 | R | Float | 2 | |
CO_PowerOnMode_1 | 4028 | Start-up mode | R/W | Enum | 0 | |
CO_PowerOnMode_2 | 4029 | Start-up mode | R/W | Enum | 0 | |
CO_PowerOnValue_1 | 402A | Start-up current | R/W | Float | 0 | |
CO_PowerOnValue_2 | 402B | Start-up current | R/W | Float | 0 | |
CO_SimulationMode_1 | 402C | Sim.curr.out. 1 (46) | R/W | Enum | 0 | |
CO_SimulationMode_2 | 402D | Sim.curr.out. 2 (46) | R/W | Enum | 0 | |
CO_SimulationValue_1 | 402E | Value curr.out1 | R/W | Float | 0 | |
CO_SimulationValue_2 | 402F | Value curr.out2 | R/W | Float | 0 | |
CO_TauDamping_1 | 4030 | Damping | R/W | Float | 0 | |
CO_TauDamping_2 | 4031 | Damping | R/W | Float | 0 | |
CO_TrimValueHi_1 | 4032 | Trim value high | R/W | Float | 0 | |
CO_TrimValueHi_2 | 4033 | Trim value high | R/W | Float | 0 | |
CO_TrimValueLo_1 | 4034 | Trim value low | R/W | Float | 0 | |
CO_TrimValueLo_2 | 4035 | Trim value low | R/W | Float | 0 | |
CO_ZoomMode_1 | 4010 | Turn down | R/W | Enum | 0 | |
CO_ZoomMode_2 | 4019 | Turn down | R/W | Enum | 0 | |
Debug_ActInstance | 4036 | R/W | Unsigned | 32 | ||
Display_ActInstance | 4037 | R/W | Unsigned | 32 | ||
DISP_AccessCode_1 | 4038 | Ent. access code | Enter access code to disable write protection of parameters | R/W | Unsigned | 256 |
DISP_AlternatingTime_1 | 4039 | Display interval (36) | Set time measured values are shown on display if display alternates between values | R/W | Float | 256 |
DISP_BackLight_1 | 403B | Backlight | Switch the local display backlight on and off | R/W | Enum | 256 |
DISP_BackupAction_1 | 403D | Config. managem. (39) | Select action for managing the device data in the display module | R/W | Enum | 256 |
DISP_BackupStatus_1 | 4042 | Backup state | R/W | Enum | 2 | |
Name | ID | Label | Description | Type | Access | Class |