Name ID Label Description Type Access Class
physical_layer_type_codes 0800 R/W Enum 4096
lock_device_status_codes 07FE R/W Enum 4096
analog_channel_flags 0802 R/W Enum 4096
process_data_status 0804 R/W Enum 4096
limit_status 0805 R/W Enum 4096
device_family_status 0806 R/W Enum 4096
manufacturer_id 0099 Manufacturer Manufacturer Identification Code- References a specific manufacturer, which is usually a company name, that is responsible for the manufacture of this Field Device. R Enum 128
private_label_distributor 00A8 Distributor Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers R Enum 2048
device_type 009A Model Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer R Enum 128
write_protect 00A7 Write protect Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. R Enum 2048
physical_signaling_code 00AB Physicl signl code Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port R Enum 2048
operatingMode 0870 Operate mode 1 Field Device Specific Operating Mode 1- A possible mode of operation in Field Device R Enum 2049
extended_fld_device_status 0807 Ext dev status Extended Field Device Status- This provides additional Device Status information R BitEnum 131
loop_current_mode 0808 Loop current mode Loop Current Mode- Indicates whether the loop current is active or fixed (i.e., the device is in multi-drop). R/W Enum 64
device_flags 00A0 Dev flags Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer R BitEnum 2048
analog_channel_saturated1 103D AO saturated Field Device Specific Dynamic Variable Analog Output Saturated- Data that indicates which of the Analog Outputs are, or are not, saturated. The analog and digital Analog Outputs for the Dynamic Variable are beyond their limits and no longer represent the true applied process. R BitEnum 2051
analog_channel_fixed1 1040 AO fixed Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process. R BitEnum 2051
analog_channel_saturated_codes 08D6 R/W Enum 4096
analog_channel_fixed_codes 08D7 R/W Enum 4096
response_code 0096 Response code Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. R Enum 129
comm_status 0098 Communication status Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. R BitEnum 131
request_preambles 009B Num req preams Number of Request Preambles- Number of Preambles required from the Host request by the Field Device R Unsigned 128
universal_revision 009C Universal rev Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to R Unsigned 128
transmitter_revision 009D Fld dev rev Field Device Revision- Revision of the Field Device Specific Device Description, that the Field Device conforms to R Unsigned 128
software_revision 009E Software rev Field Device Software Revision- This revision corresponds to the software or firmware, that is embedded in the Field Device R Unsigned 2048
hardware_revision 009F Hardware rev Hardware Revision- Revision that corresponds to the electronics hardware of the Field Device. R Unsigned 2048
device_id 00A1 Dev id Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. R Unsigned 2048
response_preambles 0FE2 Num resp preams Number of Response Preambles- Number of Preambles to be sent in the response message from the Field Device to the Host R Unsigned 128
max_num_device_variables 00CE Max dev vars Maximum Number of Device Variables- This indicates the last Device Variable code that a host application should expect to be found in the field device (e.g., when identifying the Device Variables using Command 54) R Unsigned 2048
config_change_counter 00CF Cfg chng count Configuration Change Counter- This indicates the number of times the devices configuration or calibration has been changed by a host application or from a local operator interface. R Unsigned 2050
tag 00A3 Cust. tag number Tag- Text that is associated with the Field Device installation. This text can be used by the user in any way. A recommended use is as a unique label to a plant that correlates to a Field Device label: a plant drawing, or on a Control System. This variable is also used as a type of data link layer address handle. R/W PackedAscii 2048
longTag 00D2 Long tag Long Tag- Functions exactly like Tag except the size is larger (max of 32 ISO Latin 1 characters). R/W ASCII 2048
device_variable_code_1 00E1 R/W Index 4096
device_variable_code_2 00E2 R/W Index 4096
device_variable_code_3 00E3 R/W Index 4096
device_variable_code_4 00E4 R/W Index 4096
polling_address 00A2 Poll addr Polling Address- Address used by the Host to identify a Field Device, and changeable by the User to control: the Multidrop Mode for Analog Output 1), and the Analog Output Fixed Mode of Analog Output 1) R/W Unsigned 128
message 00A4 Message Message- Text that is associated with the Field Device. This text can be used by the user in any way. There is no recommended use. R/W PackedAscii 2048
descriptor 00A5 Descriptor Descriptor- Text that is associated with the Field Device. This text can be used by the user in any way. There is no specific recommended use. R/W PackedAscii 2048
date 00A6 Date Date- Gregorian calendar date that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. R/W HartDate 2048
final_assembly_number 00A9 Final asmbly num Final Assembly Number- Number that is used for identification purposes, and is associated with the overall Field Device. R/W Unsigned 2048
loopCurrent 00ED Loop current Loop Current- Loop current value as perceived by the device. R Float 66
loop_alarm_code 00EC AO Alrm typ Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R Enum 64
loop_flags 00E7 Channel flags Analog Channel Flags- Defines the characteristics of the Analog Channel R BitEnum 64
percentRange 00E9 PV % rnge Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
transfer_function 1F84 Xfer fnctn Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. R Enum 32
upperRange_value 00EA PV URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
lowerRange_value 00EB PV LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
primary_variable_code 0FD0 PV is Primary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Primary Variable dynamic variable R/W Index 128
secondary_variable_code 0FD1 SV is Secondary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Secondary Variable dynamic variable R/W Index 128
Name ID Label Description Type Access Class