Loading…
Name ID Label Description Type Access Class
DeviceTypeDeltabarM 406F Device type code Display the device identification number in a decimal numerical format R Unsigned 32
DeviceTypeDeltapilotM 4070 Device type code Display the device identification number in a decimal numerical format R Unsigned 32
DeviceTypeWaterpilotM 4071 Device type code Display the device identification number in a decimal numerical format R Unsigned 32
DirectAccess 4072 Direct access Enter a display id-number for direct access R/W Unsigned 32
DisplayContrast 4073 Display contrast Adjusts the contrast of on-site display R/W Unsigned 32
DisplayLanguage 4074 Language Selection of the menu language for the on-site display R/W Enum 32
DisplayMainline1Content 4075 Display mode Specifies the contents for the main line of the on-site display in the measuring mode R/W Enum 32
DisplayMainline2Content 4076 Add. disp. value Specifies the contents for the alternating line of the on-site display in the measuring mode R/W Enum 32
DisplayMainlineFormat 4077 Format 1st value R Enum 2
DownloadOverwriteSelection 4078 Download select. Selection of the download function from HistoROM to device R/W Enum 32
DynamicDisplayLanguage 4079 Language Selection of the menu language for the on-site display R/W Enum 32
DynamicDisplayMainline2Content 407B Add. disp. value Specifies the contents for the alternating line of the on-site display in the measuring mode R/W Enum 32
DynamicOperatingMode 407D Measuring mode The opertating menu is structured according to the selected measuring mode R/W Enum 2
ElectricDeltaPConstant 4080 Fixed ext. value R/W Float 32
ElectricDeltaPControl 4081 Electr. delta P Enables and disables the ''Electrical deltaP'' function R/W Enum 32
ElectronicSerialNumber 4082 Electr.serial no Displays the serial number of the sensor R PackedAscii 32
ENPVersion 4083 ENP version Displays the version of the electronic nameplate R ASCII 32
FlowAfterSuppression 402E Flow Displays the current flow / Depending on the flow mode selected R Float 2
FlowLowerRangeValue 4084 Set LRV Enter a flow / pressure value for the lower current value (4mA) R/W Float 32
FlowMax 4086 Max. flow Enter maximum flow of primary element R/W Float 32
FlowMaxPressure 4087 Max. press. flow Enter maximum pressure of primary element R/W Float 32
FlowMode 4085 Linear/Sqroot Specifies the current signal for the ''Flow'' measuring mode R/W Enum 2
FlowSimulationValue 4089 Sim. flow Enter simulation value R/W Float 32
FlowType 408A Flow-meas. type Selection of the flow type R/W Enum 32
FlowUnit 408C Flow unit R/W Enum 32