Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
output_transfer_function | 4001 | Xfer fnctn | R | Enum | 0 | |
dummy_unit | 4002 | Dummy unit | R/W | Enum | 4096 | |
dummy_float | 4003 | Dummy float | R/W | Float | 4096 | |
pressureValue | 4004 | Pres | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 4096 |
pressureFamily | 4005 | Pres Dev fmly | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 4096 |
pressureClassification | 4006 | Pres Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 4096 |
pressurePDQ | 4007 | Pres PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 4096 |
pressureLS | 4008 | Pres LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 4096 |
pressureStatus | 4009 | Pres Fmly stat | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 4096 |
pressureUSL | 400A | Pres USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 4096 |
pressureLSL | 400B | Pres LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 4096 |
pressureMinimumSpan | 400C | Pres min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 4096 |
pressureDampingValue | 400D | Pres damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 4096 |
pressureSerialNumber | 400E | Pres snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 4096 |
pressureLowerTrimPoint | 400F | Pres Lower trim | Lower Trim Point- Applied process input at which the last lower trim of the device variable was performed. | R | Float | 4096 |
pressureUpperTrimPoint | 4010 | Pres Upper trim | Upper Trim Point- Applied process input at which the last upper trim of the device variable was performed. | R | Float | 4096 |
pressureTrimSupport | 4011 | Pres Trim support | Trim Points Supported- Indicates the trim points that are supported by the device variable during a trim procedure. | R | Enum | 4096 |
pressureMinimumLTP | 4012 | Pres Min lower trim | Minimum Lower Trim Point- The lowest applied process value that can be used duirng a low trim procedure (ie, no value lower than this will be accepted by the instrument). | R | Float | 4096 |
pressureMaximumLTP | 4013 | Pres Max lower trim | Maximum Lower Trim Point- The highest applied process value that can be used duirng a low trim procedure (ie, no value higher than this will be accepted by the instrument). | R | Float | 4096 |
pressureMinimumUTP | 4014 | Pres Min upper trim | Minimum Upper Trim Point- The lowest applied process value that can be used duirng a high trim procedure (ie, no value lower than this will be accepted by the instrument). | R | Float | 4096 |
pressureMaximumUTP | 4015 | Pres Max upper trim | Maximum Upper Trim Point- The highest applied process value that can be used duirng a high trim procedure (ie, no value higher than this will be accepted by the instrument). | R | Float | 4096 |
pressureMinimumTrimDiff | 4016 | Pres Min trim diff | Minimum Trim Differential- The minimum acceptable difference between the upper and lower trim points. | R | Float | 4096 |
AccelerationOfGravity | 4035 | Acc. of gravity | R/W | Float | 32 | |
AcceptPressureLowerRangeValue | 4037 | Get LRV | Sets lower range value / Reference pressure is present at device | R/W | Enum | 32 |
AcceptPressureUpperRangeValue | 4038 | Get URV | Sets upper range value / Reference pressure is present at device | R/W | Enum | 32 |
ActualAlarmInfo_io | 4039 | Diagnostic code | R | Enum | 2 | |
ActualAlarmInfo0 | 403A | Diagnostic 1 | Displays current messages according to their priority | R | Enum | 2 |
ActualAlarmInfo1 | 403B | Diagnostic 2 | Displays current messages according to their priority | R | Enum | 2 |
ActualAlarmInfo2 | 403C | Diagnostic 3 | Displays current messages according to their priority | R | Enum | 2 |
ActualAlarmInfo3 | 403D | Diagnostic 4 | Displays current messages according to their priority | R | Enum | 2 |
ActualAlarmInfo4 | 403E | Diagnostic 5 | Displays current messages according to their priority | R | Enum | 2 |
ActualAlarmInfo5 | 403F | Diagnostic 6 | Displays current messages according to their priority | R | Enum | 2 |
ActualAlarmInfo6 | 4040 | Diagnostic 7 | Displays current messages according to their priority | R | Enum | 2 |
ActualAlarmInfo7 | 4041 | Diagnostic 8 | Displays current messages according to their priority | R | Enum | 2 |
ActualAlarmInfo8 | 4042 | Diagnostic 9 | Displays current messages according to their priority | R | Enum | 2 |
ActualAlarmInfo9 | 4043 | Diagnostic 10 | Displays current messages according to their priority | R | Enum | 2 |
ActualHighestAlarm | 4044 | Diagnostic code | Displays the current message with the highest priority | R | Enum | 2 |
ActualMaintenanceInstruct | 4045 | Instructions | R | Enum | 2 | |
ActualMaintenanceInstruct0 | 4046 | Instructions 1 | R | Enum | 2 | |
ActualMaintenanceInstruct1 | 4047 | Instructions 2 | R | Enum | 2 | |
ActualMaintenanceInstruct2 | 4048 | Instructions 3 | R | Enum | 2 | |
ActualMaintenanceInstruct3 | 4049 | Instructions 4 | R | Enum | 2 | |
ActualMaintenanceInstruct4 | 404A | Instructions 5 | R | Enum | 2 | |
ActualMaintenanceInstruct5 | 404B | Instructions 6 | R | Enum | 2 | |
ActualMaintenanceInstruct6 | 404C | Instructions 7 | R | Enum | 2 | |
ActualMaintenanceInstruct7 | 404D | Instructions 8 | R | Enum | 2 | |
ActualMaintenanceInstruct8 | 404E | Instructions 9 | R | Enum | 2 | |
ActualMaintenanceInstruct9 | 404F | Instructions 10 | R | Enum | 2 | |
AfterLinearizationUnit | 4050 | Unit after lin. | Selection of the volume unit | R/W | Enum | 32 |
AlarmBehaviourValue | 4051 | Output fail mode | R/W | Enum | 2 | |
Name | ID | Label | Description | Type | Access | Class |