Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
conc3DampingValue | 4049 | Conc damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R | Float | 0 |
conc3UpdatePeriod | 404A | Conc Update Period | R | Time | 0 | |
conc3SerialNumber | 404B | Conc snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R/W | Unsigned | 2048 |
conc3Simulated | 404C | Simulate | W | Enum | 2052 | |
conc4Value | 404E | Concentration | Concentration value measured by device variable 4 | R | Float | 10 |
conc4Units | 404F | Concentration unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 8 |
conc4Family | 4050 | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 2048 | |
conc4Classification | 4051 | Conc Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
conc4PDQ | 4052 | Conc PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 10 |
conc4LS | 4053 | Conc LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 10 |
Name | ID | Label | Description | Type | Access | Class |