Loading…
Name ID Label Description Type Access Class
temperature2PDQ 4034 Temperature PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 10
temperature2LS 4035 Temperature LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 10
temperature2Status 4036 Temperature Fmly stat Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 10
temperature2USL 4037 Temp USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 0
temperature2LSL 4038 Temp LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 0
temperature2MinimumSpan 4039 Temp min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
temperature2DampingValue 403A Temp damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R Float 0
temperature2UpdatePeriod 403B Temperature Update Period R Time 0
temperature2SerialNumber 403C Temp snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R Unsigned 2048
temperature2Simulated 403D Simulate W Enum 2052
Name ID Label Description Type Access Class