Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
temperature2PDQ | 4034 | Temperature PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 10 |
temperature2LS | 4035 | Temperature LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 10 |
temperature2Status | 4036 | Temperature Fmly stat | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 10 |
temperature2USL | 4037 | Temp USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 0 |
temperature2LSL | 4038 | Temp LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 0 |
temperature2MinimumSpan | 4039 | Temp min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 0 |
temperature2DampingValue | 403A | Temp damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R | Float | 0 |
temperature2UpdatePeriod | 403B | Temperature Update Period | R | Time | 0 | |
temperature2SerialNumber | 403C | Temp snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 2048 |
temperature2Simulated | 403D | Simulate | W | Enum | 2052 | |
Name | ID | Label | Description | Type | Access | Class |