Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
SnsrVolConcMaximumLTP | 40CF | Conc Max lower trim | Maximum Lower Trim Point- The highest applied process value that can be used duirng a low trim procedure (ie, no value higher than this will be accepted by the instrument). | R | Float | 0 |
SnsrVolConcMinimumUTP | 40D0 | Conc Min upper trim | Minimum Upper Trim Point- The lowest applied process value that can be used duirng a high trim procedure (ie, no value lower than this will be accepted by the instrument). | R | Float | 0 |
SnsrVolConcMaximumUTP | 40D1 | Conc Max upper trim | Maximum Upper Trim Point- The highest applied process value that can be used duirng a high trim procedure (ie, no value higher than this will be accepted by the instrument). | R | Float | 0 |
SnsrVolConcMinimumTrimDiff | 40D2 | Conc Min trim diff | Minimum Trim Differential- The minimum acceptable difference between the upper and lower trim points. | R | Float | 0 |
SnsrTemperatureValue | 40D4 | Snsr 1 Temp | Sensor 1 Temperature | R | Float | 10 |
SnsrTemperatureUnits | 40D5 | Snsr Temp unit | Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. | R | Enum | 8 |
SnsrTemperatureFamily | 40D6 | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 2048 | |
SnsrTemperatureClassification | 40D7 | Temperature Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
SnsrTemperaturePDQ | 40D8 | Temperature PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 10 |
SnsrTemperatureLS | 40D9 | Temperature LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 10 |
Name | ID | Label | Description | Type | Access | Class |